          18906011628

          大鼠繆勒管抑制物質(zhì)/抗繆勒管激素(AMH)ELISA試劑盒使用說明

          時間:2014/4/12閱讀:141
          分享:

          大鼠繆勒管抑制物質(zhì)/抗繆勒管激素(AMH)ELISA試劑盒使用說明

          1
          Rat anti-mullerian hormone (AMH) ELISA kit 
          For the quantitative determination of rat anti-mullerian hormone (AMH) 
          concentrations in serum, plasma and tissue homogenates. 
          This package insert must be read in its entirety before using this product. 

          In order to obtain higher efficiency service, please ready to supply the lot number 
          of the kit to us (found on the outside of the box).2
          PRINCIPLE OF THE ASSAY
          This assay employs the competitive enzyme immunoassay technique. The 
          microtiter plate provided in this kit has been pre-coated with goat-anti-rabbit 
          antibody. Standards or samples are added to the appropriate microtiter plate 
          wells with an antibody specific for AMH and Horseradish Peroxidase (HRP) 
          conjugated AMH. The competitive inhibition reaction is launched between with 
          HRP labeled AMH and unlabeled AMH with the antibody. A substrate solution is 
          added to the wells and the color develops in opposite to the amount of AMH in 
          the sample. The color development is stopped and the intensity of the color is 
          measured. 
          DETECTION RANGE
          0.375 ng/ml-150 ng/ml. 
          SENSITIVITY
          The minimum detectable dose of rat AMH is typically less than 0.375 ng/ml. 
          The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as 
          the lowest rat AMH concentration that could be differentiated from zero. It was 
          determined the mean O.D value of 20 replicates of the zero standard added by 
          their three standard deviations. 
          SPECIFICITY
          This assay has high sensitivity and excellent specificity for detection of rat AMH. 
          No significant cross-reactivity or interference between rat AMH and analogues 
          was observed. 
          Note: Limited by current skills and knowledge, it is impossible for us to complete 
          the cross-reactivity detection between rat AMH and all the analogues, therefore, 
          cross reaction may still exist. 3
          PRECISION 
          Intra-assay Precision (Precision within an assay): CV%<15%
          Three samples of known concentration were tested twenty times on one plate to 
          assess.  
          Inter-assay Precision (Precision between assays): CV%<15%
          Three samples of known concentration were tested in twenty assays to assess.  
          LIMITATIONS OF THE PROCEDURE
          FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC 
          PROCEDURES. 
          The kit should not be used beyond the expiration date on the kit label. 
          Do not mix or substitute reagents with those from other lots or sources. 
          If samples generate values higher than the highest  standard, dilute the 
          samples and repeat the assay. 
          Any variation in operator, pipetting technique, washing technique, 
          incubation time or temperature, and kit age can cause variation in binding. 
          This assay is designed to eliminate interference by soluble receptors, 
          binding proteins, and other factors present in biological samples. Until all 
          factors have been tested in the Immunoassay, the possibility of 
          interference cannot be excluded. 4
          MATERIALS PROVIDED
          Reagents  Quantity 
          Assay plate  1(96 wells) 
          Standard  6 x 0.5 ml 
          Antibody    1 x 6 ml 
          HRP-conjugate   1 x 6 ml 
          Wash Buffer (20 x concentrate) 1 x 15 ml 
          Substrate A  1 x 7 ml 
          Substrate B  1 x 7 ml 
          Stop Solution    1 x 7 ml 
          Adhesive Strip (For 96 wells) 4 
          Instruction manual  1 
          STANDARD CONCENTRATION
          Standard S0 S1 S2 S3 S4 S5 
          Concentration
          (ng/ml) 
          0 0.375 1.313 4.69 28.13 150 
          STORAGE
          Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date.
          Opened kit May be stored for up to 1 month at 2 - 8° C. 
          *Provided this is within the expiration date of the kit.
          OTHER SUPPLIES REQUIRED
          Microplate reader capable of measuring absorbance at 450 nm, with the 
          correction wavelength set at 600 nm - 630 nm. 
          An incubator which can provide stable incubation conditions up to 
          37°C±0.5°C. 
          Squirt bottle, manifold dispenser, or automated microplate washer. 
          Absorbent paper for blotting the microtiter plate. 5
          100 mL and 500 mL graduated cylinders. 
          Deionized or distilled water. 
          Pipettes and pipette tips. 
          Test tubes for dilution. 
          PRECAUTIONS
          The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, 
          and clothing protection when using this material. 
          SAMPLE COLLECTION AND STORAGE
          Serum  Use a serum separator tube (SST) and allow samples to clot for 
          two hours at room temperature or overnight at 4°C before centrifugation 
          for 15 minutes at 1000 ×g. Remove serum and assay immediay or 
          aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw 
          cycles. 
          Plasma  Collect plasma using EDTA, or heparin as an anticoagulant. 
          Centrifuge for 15 minutes at 1000 ×g at 2-8°C within 30 minutes of 
          collection. Assay immediay or aliquot and store  samples at -20°C or 
          -80°C. Avoid repeated freeze-thaw cycles. 
          Tissue Homogenates    100mg tissue was rinsed with 1X PBS, 
          homogenized in 1 ml of 1X PBS and stored overnight at -20°C. After two 
          freeze-thaw cycles were performed to break the cell membranes, the 
          homogenates were centrifuged for 5 minutes at 5000  x g, 2 - 8°C. The 
          supernate was assayed and removed immediay. Alternatively, aliquot 
          and store samples at -20°C or -80°C. Centrifuge the sample again after 
          thawing before the assay. Avoid repeated freeze-thaw cycles. 6
          Note: 
          1. CUSABIO is only responsible for the kit itself,  but not for the samples 
          consumed during the assay. The user should calculate the possible 
          amount of the samples used in the whole test. Please reserve sufficient 
          samples in advance. 
          2. Samples to be used within 5 days may be stored at 2-8°C, otherwise 
          samples must be stored at -20°C (≤1month) or -80°C (≤2month) to avoid 
          loss of bioactivity and contamination. 
          3. Grossly hemolyzed samples are not suitable for use in this assay. 
          4. If the samples are not indicated in the manual, a preliminary experiment to 
          determine the validity of the kit is necessary.  
          5. Please predict the concentration before assaying. If values for these are 
          not within the range of the standard curve, users must determine the 
          optimal sample dilutions for their particular experiments. 
          6. Tissue or cell extraction samples prepared by chemical lysis buffer may 
          cause unexpected ELISA results due to the impacts of certain chemicals. 
          7. Owing to the possibility of mismatching between  antigen from other 
          resource and antibody used in our kits (e.g., antibody targets 
          conformational epitope rather than linear epitope), some native or 
          recombinant proteins from other manufacturers may not be recognized by 
          our products. 
          8. Influenced by the factors including cell viability, cell number and also 
          sampling time, samples from cell culture supernatant may not be detected 
          by the kit. 
          9. Fresh samples without long time storage are recommended for the test. 
          Otherwise, protein degradation and denaturalization may occur in those 
          samples and finally lead to wrong results. 7
          REAGENT PREPARATION
          Note:  
          Kindly use graduated containers to prepare the reagent.  
          Bring all reagents to room temperature (18-25°C) before use for 30min.
          Distilled water is recommended to be used to make the preparation for 
          reagents or samples. Contaminated water or container for reagent 
          preparation will influence the detection result. 
          Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to   
          room temperature and mix gently until the crystals  have compley 
          dissolved. Dilute 15 ml of Wash Buffer Concentrate (20 x) into deionized or 
          distilled water to prepare 300 ml of Wash Buffer (1 x). 8
          ASSAY PROCEDURE 
          Bring all reagents and samples to room temperature before use. Centrifuge 
          the sample again after thawing before the assay. It is recommended that all 
          samples and standards be assayed in duplicate. 
          1. Prepare all reagents and samples as directed in the previous sections. 
          2. Determine the number of wells to be used and put any remaining wells 
          and the desiccant back into the pouch and seal the ziploc, store unused 
          wells at 4°C. 
          3. Set a Blank well without any solution.  
          4. Add 50µl of Standard or Sample per well. Standard need test in duplicate.  
          5. Add 50µl of  HRP-conjugate to each well (not to Blank well), then 50µl 
          Antibody to each well. Mix well and then incubate for 60 minutes at 37°C.  
          6. Aspirate each well and wash, repeating the process two times for a total of 
          three washes. Wash by filling each well with Wash Buffer (200µl) using a 
          squirt bottle, multi-channel pipette, manifold dispenser, or autowasher, 
          and let it stand for 10 seconds, complete removal of liquid at each step is 
          essential to good performance. After the last wash, remove any remaining 
          Wash Buffer by aspirating ordecanting. Invert the plate and blot it against 
          clean paper towels. 
          7. Add 50µl of Substrate A and 50µl of Substrate B to each well, mix well. 
          Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and 
          other temperature fluctuations in the dark. 
          8. Add 50µl of Stop Solution to each well, gently tap the plate to ensure 
          thorough mixing.  
          9. Determine the optical density of each well within 10 minutes, using a 
          microplate reader set to 450 nm. 9
          Note: 
          1. The final experimental results will be closely related to validity of the 
          products, operation skills of the end users and the experimental 
          environments.  
          2. Samples or reagents addition: Please carefully add samples to wells and 
          mix gently to avoid foaming. Do not touch the well wall as possible. For 
          each step in the procedure, total dispensing time for addition of reagents 
          or samples to the assay plate should not exceed 10  minutes. This will 
          ensure equal elapsed time for each pipetting step,  without interruption. 
          Duplication of all standards and specimens, although not required, is 
          recommended. To avoid cross-contamination, change pipette tips 
          between additions of each standard level, between sample additions, and 
          between reagent additions. Also, use separate reservoirs for each 
          reagent. 
          3. Incubation: To ensure accurate results, proper adhesion of plate sealers 
          during incubation steps is necessary. Do not allow wells to sit uncovered 
          for extended periods between incubation steps. Once reagents have been 
          added to the well strips, DO NOT let the strips DRY at any time during the 
          assay. Incubation time and temperature must be observed. 
          4. Washing: The wash procedure is critical. Complete removal of liquid at 
          each step is essential to good performance. After the last wash, remove 
          any remaining Wash Solution by aspirating or decanting and remove any 
          drop of water and fingerprint on the bottom of the  plate. Insufficient 
          washing will result in poor precision and falsely elevated absorbance 
          reading. When using an automated plate washer, adding a 10 second 
          soak period following the addition of wash buffer, and/or rotating the plate 
          180 degrees between wash steps may improve assay precision. 
          5. Controlling of reaction time: Observe the change of color after adding 
          Substrates (e.g. observation once every 10 minutes). Substrates should 
          change from colorless or light blue to gradations of blue. If the color is too 
          deep, add Stop Solution in advance to avoid excessively strong reaction 
          which will result in inaccurate absorbance reading.
          6. Substrates are easily contaminated. Substrates should remain colorless or 
          light blue until added to the plate. Please protect it from light. 
          7. Stop Solution should be added to the plate in the same order as the 
          Substrates. The color developed in the wells will turn from blue to yellow 
          upon addition of the Stop Solution. Wells that are green in color indicate 
          that the Stop Solution has not mixed thoroughly with the Substrates.10
          ASSAY PROCEDURE SUMMARY 11
          CALCULATION OF RESULTS 
          Using the professional soft "Curve Expert 1.3" to make a standard curve is 
          recommended, which can be downloaded from our web. 
          Average the duplicate readings for each standard and sample and subtract the 
          average optical density of Blank.  
          Create a standard curve by reducing the data using computer software capable 
          of generating a four parameter logistic (4-PL) curve-fit. As an alternative, 
          construct a standard curve by plotting the mean absorbance for each standard 
          on the x-axis against the concentration on the y-axis and draw a best fit curve 
          through the points on the graph. The data may be linearized by plotting the log of 
          the AMH concentrations versus the log of the O.D. and the best fit line can be 
          determined by regression analysis. This procedure will produce an adequate but 
          less precise fit of the data.  
          If samples have been diluted, the concentration read from the standard curve 
          must be multiplied by the dilution factor. 12
          Notes 13141516

          慧嘉生物您實驗身邊的好伙伴

          為客戶提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”

          詳細(xì)說明書及技術(shù)咨詢 

           陳

          :1193953234      1048735792

          會員登錄

          ×

          請輸入賬號

          請輸入密碼

          =

          請輸驗證碼

          收藏該商鋪

          X
          該信息已收藏!
          標(biāo)簽:
          保存成功

          (空格分隔,最多3個,單個標(biāo)簽最多10個字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時間回復(fù)您~
          撥打電話
          在線留言
          灵丘县| 海林市| 辽中县| 长乐市| 新竹市| 天镇县| 察隅县| 平昌县| 太仓市| 云浮市| 海宁市| 阿拉尔市| 禄丰县| 玉门市| 额济纳旗| 金昌市| 临湘市| 藁城市| 扶沟县| 环江| 漠河县| 定安县| 五大连池市| 沅陵县| 石屏县| 潜山县| 柏乡县| 武夷山市| 长葛市| 庄河市| 河源市| 奉节县| 普兰店市| 章丘市| 柘城县| 磐石市| 绵竹市| 库伦旗| 林甸县| 安泽县| 武定县|