          大鼠熱休克因子1(HSF1)ELISA試劑盒使用說(shuō)明

          時(shí)間:2014/4/16閱讀:238
          分享:

          大鼠熱休克因子1(HSF1)ELISA試劑盒使用說(shuō)明

          1
          Rat Heat Shock Factor 1 (HSF1) ELISA Kit
          Catalog Number. CSB-E09845r
          For  the quantitative  determination of  rat heat shock factor 1 (HSF1)
          concentrations in serum, plasma, tissue homogenates, cell lysates.
          This package insert must be read in its entirety before using this product.

          In order to obtain higher efficiency service, please ready to supply the lot number 
          of the kit to us (found on the outside of the box).2
          PRINCIPLE OF THE ASSAY
          This assay employs the quantitative sandwich enzyme immunoassay technique. 
          Antibody specific for HSF1 has been pre-coated onto a microplate. Standards 
          and samples are pipetted into the wells and any HSF1 present is bound by the 
          immobilized antibody. After  removing  any unbound substances, a 
          biotin-conjugated antibody specific for HSF1 is added to the wells. After washing,
          avidin conjugated Horseradish Peroxidase (HRP) is added to the wells.
          Following a wash to remove any unbound avidin-enzyme reagent, a substrate 
          solution is added to the wells and color develops in proportion to the amount of 
          HSF1 bound in the initial step. The color development is stopped and the 
          intensity of the color is measured.
          DETECTION RANGE
          1.25 ng/ml-80 ng/ml.
          SENSITIVITY
          The minimum detectable dose of rat HSF1 is typically less than 0.31 ng/ml.
          The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as 
          the lowest protein concentration that could be differentiated from zero. It was 
          determined the mean O.D value of 20 replicates of the zero standard added by 
          their three standard deviations.
          SPECIFICITY
          This assay has high sensitivity and excellent specificity for detection of rat HSF1. 
          No significant cross-reactivity or interference between rat HSF1 and analogues 
          was observed.
          Note: Limited by current skills and knowledge, it is impossible for us to complete 
          the cross-reactivity detection between rat HSF1 and all the analogues, therefore,
          cross reaction may still exist.3
          PRECISION
          Intra-assay Precision (Precision within an assay): CV%<8%
          Three samples of known concentration were tested twenty times on one plate to 
          assess.
          Inter-assay Precision (Precision between assays): CV%<10%
          Three samples of known concentration were tested in twenty assays to assess.
          LIMITATIONS OF THE PROCEDURE
          ? FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC 
          PROCEDURES.
          ? The kit should not be used beyond the expiration date on the kit label.
          ? Do not mix or substitute reagents with those from other lots or sources.
          ? If samples generate values higher than the highest standard, dilute the 
          samples with Sample Diluent and repeat the assay.
          ? Any variation in  Sample Diluent, operator, pipetting technique, washing 
          technique, incubation time or temperature, and kit age can cause variation 
          in binding.
          ? This assay is designed to eliminate interference by soluble receptors, 
          binding proteins, and other factors present in biological samples. Until all 
          factors have been tested in the Immunoassay, the possibility of 
          interference cannot be excluded.4
          MATERIALS PROVIDED
          Reagents Quantity
          Assay plate (12 x 8 coated Microwells) 1(96 wells)
          Standard (Freeze dried) 2
          Biotin-antibody (100 x concentrate) 1 x 120 μl
          HRP-avidin (100 x concentrate) 1 x 120 μl
          Biotin-antibody Diluent   1 x 10 ml
          HRP-avidin Diluent    1 x 10 ml
          Sample Diluent   1 x 20 ml
          Wash Buffer (25 x concentrate) 1 x 20 ml
          TMB Substrate  1 x 10 ml
          Stop Solution   1 x 10 ml
          Adhesive Strip (For 96 wells) 4
          Instruction manual 1
          STORAGE
          Unopened kit Store at 2 - 8°C. Do not use past kit expiration date
          Opened kit
          Coated assay 
          plate
          May be stored for up to 1 month at 2 - 8°C. 
          Try to keep it in a sealed aluminum foil bag,
          and avoid the damp.
          Standard May be stored for up to 1 month at 2 - 8° C. If 
          don’t make recent use, better keep it store at 
          -20°C.
          Biotin-antibody 
          HRP-avidin
          Biotin-antibody 
          Diluent
          May be stored for up to 1 month at 2 - 8°C.
          HRP-avidin 
          Diluent
          Sample 
          Diluent
          Wash Buffer
          TMB 
          Substrate
          Stop Solution
          *Provided this is within the expiration date of the kit.5
          OTHER SUPPLIES REQUIRED
          ? Microplate reader capable of measuring absorbance at 450 nm, with the 
          correction wavelength set at 540 nm or 570 nm.
          ? An incubator which can provide stable incubation conditions up to 
          37°C±0.5°C.
          ? Squirt bottle, manifold dispenser, or automated microplate washer.
          ? Absorbent paper for blotting the microtiter plate.
          ? 100 mL and 500 mL graduated cylinders.
          ? Deionized or distilled water.
          ? Pipettes and pipette tips.
          ? Test tubes for dilution.
          PRECAUTIONS
          The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, 
          and clothing protection when using this material.6
          SAMPLE COLLECTION AND STORAGE
          ? Serum Use a serum separator tube (SST) and allow samples to clot for 
          two hours at room temperature or overnight at 4°C before centrifugation 
          for  15 minutes at 1000  ×g. Remove serum and assay immediay or 
          aliquot and store samples at -20°C or -80°C. Avoid repeated freeze-thaw 
          cycles.
          ? Plasma Collect plasma using EDTA, or heparin as an anticoagulant. 
          Centrifuge for 15 minutes at 1000  ×g at 2-8°C within 30 minutes of 
          collection. Assay immediay or aliquot and store samples at  -20°C or
          -80°C. Avoid repeated freeze-thaw cycles.
          ? Tissue Homogenates    100mg tissue was rinsed with 1X PBS, 
          homogenized in 1 ml of 1X PBS and stored overnight at -20°C. After two 
          freeze-thaw cycles were performed to break the cell membranes, the 
          homogenates were centrifuged for 5 minutes at 5000 x g, 2  - 8°C. The 
          supernate was assayed and removed immediay. Alternatively, aliquot 
          and store samples at -20°C or -80°C. Centrifuge the sample again after 
          thawing before the assay. Avoid repeated freeze-thaw cycles.
          ? Cell lysates  Remove media and rinse cells  once with ice-cold PBS 
          (PH7.2-7.4). Scrape cells off the plate and transfer to an appropriate tube. 
          Dilute cell suspension with 1xPBS (PH7.2-7.4), until cell concentration 
          reached 100 million/ml. Then store overnight at  -20°C. After two 
          freeze-thaw cycles to break up the cell membranes, the cell lysates were 
          centrifuged for 5 minutes at 5000 g, 2 - 8°C. Collect the supernatant. Cell 
          lysates should be assayed immediay or aliquotted and stored at -20°C. 
          Centrifuge the sample again after thawing before the  assay. Avoid 
          repeated freeze-thaw cycles.7
          Note:
          1. CUSABIO is only responsible for the kit itself, but not for the samples 
          consumed during the assay. The user should calculate the possible 
          amount of the samples used in the whole test. Please reserve sufficient 
          samples in advance.
          2. Samples to be used within 5 days may be stored at 2-8°C, otherwise 
          samples must be stored at -20°C (≤1month) or -80°C (≤2month) to avoid 
          loss of bioactivity and contamination.
          3. Grossly hemolyzed samples are not suitable for use in this assay.
          4. If the samples are not indicated in the manual, a preliminary experiment to 
          determine the validity of the kit is necessary. 
          5. Please predict the concentration before assaying. If values for these are 
          not within the range of the standard curve, users must determine the 
          optimal sample dilutions for their particular experiments.
          6. Tissue or cell extraction samples prepared by chemical lysis buffer may 
          cause unexpected ELISA results due to the impacts of certain chemicals.
          7. Owing to the possibility of mismatching between antigen from other 
          resource and antibody used in our kits (e.g., antibody targets 
          conformational epitope rather than linear epitope), some native or 
          recombinant proteins from other manufacturers may not be recognized by 
          our products.
          8. Influenced by the factors including cell viability, cell number and also 
          sampling time, samples from cell culture supernatant may not be detected 
          by the kit.
          9. Fresh samples without long time storage are recommended for the test. 
          Otherwise, protein degradation and denaturalization may occur in those 
          samples and finally lead to wrong results.8
          REAGENT PREPARATION
          Note: 
          ? Kindly use graduated containers to prepare the reagent. Please don't 
          prepare the reagent directly in the Diluent vials provided in the kit.
          ? Bring all reagents to room temperature (18-25°C) before use for 30min.
          ? Prepare fresh standard for each assay. Use within 4 hours and discard 
          after use.
          ? Making serial dilution in the wells directly is not permitted. 
          ? Please carefully reconstitute Standards according to the instruction, and 
          avoid foaming and mix gently until the crystals have compley dissolved. 
          To minimize imprecision caused by pipetting, use small volumes and 
          ensure that pipettors are calibrated. It is recommended to suck more than 
          10μl for once pipetting.
          ? Distilled water is recommended to be used to make the preparation for 
          reagents or samples. Contaminated water or container for reagent 
          preparation will influence the detection result.
          1. Biotin-antibody (1x) - Centrifuge the vial before opening. 
          Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution 
          is 10 μl of Biotin-antibody + 990 μl of Biotin-antibody Diluent.
          2. HRP-avidin (1x) - Centrifuge the vial before opening.
          HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 
          μl of HRP-avidin + 990 μl of HRP-avidin Diluent.
          3. Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to    
          room temperature and mix gently until the crystals have compley 
          dissolved. Dilute 20 ml of Wash Buffer Concentrate (25 x) into deionized or 
          distilled water to prepare 500 ml of Wash Buffer (1 x).9
          4. Standard 
          Centrifuge the standard vial at 6000-10000rpm for 30s. 
          Reconstitute the  Standard with 1.0 ml of  Sample Diluent. Do not 
          substitute other diluents. This reconstitution produces a stock solution of 
          80 ng/ml. Mix the standard to ensure complete reconstitution and allow the 
          standard to sit for a minimum of 15 minutes with gentle agitation prior to 
          making dilutions. 
          Pipette 250 μl of Sample Diluent into each tube (S0-S6). Use the stock 
          solution to produce a 2-fold dilution series (below). Mix each tube 
          thoroughly before the next transfer. The undiluted Standard serves as the 
          high standard (80 ng/ml). Sample Diluent serves as the zero standard (0 
          ng/ml).
          Tube S7 S6 S5 S4 S3 S2 S1 S0
          ng/ml 80 40 20 10 5 2.5 1.25 010
          ASSAY PROCEDURE
          Bring all reagents and samples to room temperature before use. Centrifuge 
          the sample again after thawing before the assay. It is recommended that all 
          samples and standards be assayed in duplicate. 
          1. Prepare all reagents, working standards, and samples as directed in the 
          previous sections.
          2. Refer to the Assay Layout Sheet to determine the number of wells to be 
          used and put any remaining wells and the desiccant back into the pouch 
          and seal the ziploc, store unused wells at 4°C.
          3. Add 100μl of standard and sample per well. Cover with the adhesive strip
          provided. Incubate for 2 hours at 37°C. A plate layout is provided to record 
          standards and samples assayed.
          4. Remove the liquid of each well, don’t wash. 
          5. Add 100μl of  Biotin-antibody (1x)  to each well. Cover with a new
          adhesive strip. Incubate for 1 hour at 37°C.  (Biotin-antibody (1x) may 
          appear cloudy. Warm up to room temperature and mix gently until solution 
          appears uniform.)
          6. Aspirate each well and wash, repeating the process two times for a total of 
          three washes. Wash by filling each well with Wash Buffer (200μl) using a 
          squirt bottle, multi-channel pipette, manifold dispenser, or autowasher,
          and let it stand for 2 minutes, complete removal of liquid at each step is 
          essential to good performance. After the last wash, remove any remaining 
          wash Buffer by aspirating ordecanting. Invert the plate and blot it against 
          clean paper towels.
          7. Add 100μl of HRP-avidin (1x) to each well. Cover the microtiter plate with 
          a new adhesive strip. Incubate for 1 hour at 37°C.
          8. Repeat the aspiration/wash process for five times as in step 6.
          9. Add 90μl of TMB Substrate to each well. Incubate for 15-30 minutes at 
          37°C. Protect from light.
          10. Add 50μl of Stop Solution to each well,  gently tap the plate to ensure 
          thorough mixing.11
          11. Determine the optical density of each well within  5 minutes, using a 
          microplate reader set to 450 nm. If wavelength correction is available, set 
          to 540 nm or 570 nm. Subtract readings at 540 nm or 570 nm from the 
          readings at 450 nm. This subtraction will correct for optical imperfections 
          in the plate. Readings made directly at 450 nm without correction may be 
          higher and less accurate.
          *Samples may require dilution. Please refer to Sample Preparation section.
          Note:
          1. The final experimental results will be closely related to validity of the 
          products, operation skills of the end users and the experimental 
          environments. 
          2. Samples or reagents addition: Please use the freshly prepared Standard. 
          Please carefully add samples to wells and mix gently to avoid foaming. Do 
          not touch the well wall as possible. For each step in the procedure, total 
          dispensing time for addition of reagents or samples to the assay plate 
          should not exceed 10 minutes. This will ensure equal elapsed time for 
          each pipetting step, without interruption. Duplication of all standards and 
          specimens, although not required, is recommended. To avoid 
          cross-contamination, change pipette tips between additions of each 
          standard level, between sample additions, and between reagent additions. 
          Also, use separate reservoirs for each reagent.
          3. Incubation: To ensure accurate results, proper adhesion of plate sealers 
          during incubation steps is necessary. Do not allow wells to sit uncovered 
          for extended periods between incubation steps. Once reagents have been 
          added to the well strips, DO NOT let the strips DRY at any time during the 
          assay. Incubation time and temperature must be observed.
          4. Washing: The wash procedure is critical. Complete removal of liquid at 
          each step is essential to good performance. After the last wash, remove 
          any remaining Wash Solution by aspirating or decanting and remove any 
          drop of water and fingerprint on the bottom of the plate. Insufficient 
          washing will result in poor precision and falsely elevated absorbance 
          reading. When using an automated plate washer, adding a 30 second 
          soak period following the addition of wash buffer, and/or rotating the plate 
          180 degrees between wash steps may improve assay precision.12
          5. Controlling of reaction time: Observe the change of color after adding TMB 
          Substrate (e.g. observation once every 10 minutes), TMB Substrate
          should change from colorless or light blue to gradations of blue. If the color 
          is too deep, add Stop Solution in advance to avoid excessively strong 
          reaction which will result in inaccurate absorbance reading.
          6. TMB Substrate is easily contaminated.  TMB Substrate should remain 
          colorless or light blue until added to the plate. Please protect it from light.
          7. Stop Solution should be added to the plate in the same order as the TMB 
          Substrate. The color developed in the wells will turn from blue to yellow 
          upon addition of the Stop Solution. Wells that are green in color indicate 
          that the Stop Solution has not mixed thoroughly with the TMB Substrate.13
          ASSAY PROCEDURE SUMMARY
          *Samples may require dilution. Please refer to Sample Preparation section.14
          CALCULATION OF RESULTS
          Using the professional soft "Curve Expert 1.3" to make a standard curve is 
          recommended, which can be downloaded from our web.
          Average the duplicate readings for each standard and sample and subtract the 
          average zero standard optical density. 
          Create a standard curve by reducing the data using computer software capable 
          of generating a four parameter logistic (4-PL) curve-fit. As an alternative, 
          construct a standard curve by plotting the mean absorbance for each standard 
          on the x-axis against the concentration on the y-axis and draw a best fit curve 
          through the points on the graph. The data may be linearized by plotting the log of 
          the HSF1 concentrations versus the log of the O.D. and the best fit line can be 
          determined by regression analysis. This procedure will produce an adequate but 
          less precise fit of the data. 
          If samples have been diluted,  the concentration read from the standard curve 
          must be multiplied by the dilution factor.

          慧嘉生物您實(shí)驗(yàn)身邊的好伙伴

          為客戶(hù)提供“zui高品質(zhì)的產(chǎn)品”和“zui的服務(wù)”

          詳細(xì)說(shuō)明書(shū)及技術(shù)咨詢(xún) 

           陳

          :1193953234      1048735792

          會(huì)員登錄

          ×

          請(qǐng)輸入賬號(hào)

          請(qǐng)輸入密碼

          =

          請(qǐng)輸驗(yàn)證碼

          收藏該商鋪

          X
          該信息已收藏!
          標(biāo)簽:
          保存成功

          (空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
          撥打電話(huà)
          在線(xiàn)留言
          耒阳市| 静宁县| 新巴尔虎左旗| 正安县| 临漳县| 临江市| 金华市| 鄢陵县| 阿荣旗| 雅安市| 巴里| 澳门| 稻城县| 儋州市| 栖霞市| 汝州市| 加查县| 嵊州市| 凌海市| 曲阜市| 双柏县| 南澳县| 延吉市| 繁峙县| 贺州市| 济宁市| 任丘市| 潼关县| 万源市| 历史| 辉南县| 安康市| 光泽县| 彭山县| 凤山县| 榆社县| 霍州市| 桃园市| 两当县| 休宁县| 唐山市|