詳細(xì)介紹
產(chǎn)品描述
美國(guó)Labomed,世界zui光度計(jì)品牌之一,其高性能、低價(jià)位、多功能性,使其在市場(chǎng)占有很高的占有率,得到了使用者得*好評(píng)!
UVS-2800型是世界上的雙光束、全波長(zhǎng)、掃描、帶寬可調(diào)、紫外/可見光分光光度計(jì)
主要特點(diǎn):
1. 基線穩(wěn)定性高
2. 的:大口徑高能量光束增大了信噪比、提高了穩(wěn)定性
3. 自動(dòng)連續(xù)檢測(cè):8位自動(dòng)樣品池可連續(xù)自動(dòng)檢測(cè)
4. 光源友好:氘燈、鎢燈方便更換、維護(hù)簡(jiǎn)便,降低了操作錯(cuò)誤的可能性
5. 大屏幕LCD液晶顯示
6. RS-232接口,可連接電腦,進(jìn)行電腦操作
技術(shù)參數(shù)
光學(xué)系統(tǒng):雙光束
波長(zhǎng)范圍:190-1100nm
帶寬:0.5、1.0、2.0、5.0nm可選
漂移:0.2%T (220nm and 340nm)
波長(zhǎng)性:0.5nm(自動(dòng)校正)
波長(zhǎng)再現(xiàn)性:0.2nm
測(cè)量方法:透過(guò)率、光吸收、能量、濃度
測(cè)量范圍:-0.3~3.0Abs(0~200%tT)
測(cè)量精度:0.002Abs(0~0.5Abs),0.004Abs(0.5~1.0Abs),0.3%T(0~100%T)
重現(xiàn)性:0.001Abs(0~0.5Abs),0.002Abs(0.5~1.0Abs),0.15%T(0~100%T)
基線:0.002Abs(190-1100nm)
基線穩(wěn)定性:0.002Abs(500nm,預(yù)熱后)
掃描速度:1400nm/min
檢測(cè)器:硅光二極管
顯示:-9999~9999
噪音:<±0.001Abs(500nm,0Abs,2nm 帶寬)
波長(zhǎng)回轉(zhuǎn)速度:3600nm/min
光源:氘燈、鎢燈
樣品池:8位自動(dòng)樣品池
尺寸:56×41×25cm
商品屬性
[產(chǎn)地] 美國(guó)
[光源] 紫外可見分光光度計(jì)
[波長(zhǎng)范圍] 190~1000nm
[波長(zhǎng)精度] ±0.5nm
[光譜帶寬] 可選帶寬
[控制方式] 自動(dòng)
[掃描方式] 帶掃描功能
[光路] 準(zhǔn)雙光束
Spectro UV-Vis Dual Beam PC
Scanning Spectrophotometer
UV-VIS Split Beam8 Auto Cell
Model UVS-2700 & UVS-2800
|
Spectro UV-Vis Split Beam PC is a precise scanning Spectrophotometer with a new design of 8 microprocessor automatic 2 row cell holder that moves noiseless with a special membrane. This Split Beam Spectro has a dual detector and a very accurate system.
Spectro UV-Vis Split Beam PC is microcomputer-controlled and has a large LCD display to work independently. It can also be linked to a computer and a printer to show Photometric and Spectral data in the PC monitor. This connection is controlled by the RS232 AND USB interface, compatible with Windows XP, & and 8, using the new UVWin 6.0 UV-VIS application software.
Spectro UV-Vis Split Beam PC is also capable of performing kinetic test by an optional Peltier constant temperature system, and can test flow through liquid by the optional Sipper Flow Through System.
Spectro UV-Vis Split Beam PC can be used as an accurate system for qualitative and quantitative analysis of analytical test, Biochemistry, Chemistry, Clinical Analysis, Pharmaceutical and Agriculture Labs, Quality control, Industry and research.
Spectro UV-Vis Split Beam PC can perform protein, nucleic acid, DNA/RNA micro and macro measurements, that can also be printed using an external HP 600/800 series printer or a PC printer.
There are 2 models of Spectro UV-Vis Split Beam PC available:
1) Spectro UV-Vis Split Beam PC with fixed bandwidth of 1 nm (UVS-2700).
2) Spectro UV-Vis Split Beam PC with variable bandwidth of 0.5, 1.0, 2.0 and 5.0 nm. (UVS-2800) is also available.
This Spectro can be used by itself or linked to a PC and comes with a USB interface to connect to the computer.
The operation manual is available in 18 available different languages.
Features
Top of the Page
Baseline Stability: The Split-beam monitoring ratio system enhances baseline stability.
Excellent Resolution: The big-caliber light path enhances the instrument’s energy, reduces its noise and raises its resolution performance.
Automatic successive measurement: The automatic eight-cell sample holder offers the automatic measurement of eight samples in succession. So it can bring about one-touch measurement of the solution of seven samples and a blank.
User-friendly light source: The light source performs an automatic interchange, selectable within the working range of the light source. The socket deuterium lamps and tungsten lamps facilitate light source replacement, simplify maintenance and reduce operation error.
Convenient Display: The large backlit LCD screen displays both photometric values and spectral curves.
Full use of Computer Technology: Being computer controlled with compatible with Windows XP, & and 8, using the new UVWin 6.0 UV-VIS application software, offering a wide range of uses and applications.
The key components are all adopted from the world famous manufacturer, such as deuterium lamp, silicon photodiode and holographic grating, which ensures the stabilization and credibility of the Instrument for extended life.
Computer System is optional (NOT INCLUDED).
Functions
Top of the Page
- Photometric Measurement: Rapid and accurate measurements of transmittance and absorbance for samples and selected wavelength are available.
- This module allows successive and automatic calibration and measurement of up to seven samples with the built-in 8-cell sample holder.
- Direct concentration results can be produced by simply entering the K-factor.
- Printout of Measured data with sample numbers in a tabular format. - Spectrum Scan: Spectra of samples on any range between 1100nm ~ 190 nm can be measured with real time visual display of spectral curves on the large LCD screen.
- Such operating parameters can be selected, as photometric mode, wavelength range, ordinate range, sampling interval and scanning speed.
- Picking out and printout of peaks and valleys for spectral curves.
- Printout of spectral curves to a printer with A4 paper. - Quantitative Measurement: Use a calibration curve to determine the concentration of unknowns at the user-selected wavelength.
- The regression of calibration curve can be made with up to 8 standards and the linear correlation coefficients be offered.
- The plot of a calibration curve is displayed on the large LCD screen.
- Instant concentration results can be produced by simply entering K-factors.
- Successive and automatic calibration and concentration measurement up to seven samples are available by the built-in 8 cell sample holder.
- Printout of the table of measured concentrations and K-factors of a calibration curve. - Windows Software: Such operations as photometry measurement, spectrum measurement, quantitation measurement and kinetic measurement are offered in the UV-Win Windows application.
- Up to 10 Spectra and time-course curves can be measured and recalled in memory with data-handling of arithmetic calculation, logarithmic calculation, reciprocal calculation, smooth, derivative (1t-4th), Abs to/from %T conversion and peak pick.
- Up to 24 standards can be entered and measured for fitting of calibration curve with order of 1st – 4th.
- With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.
Software specifications
OUR NEW SOFTWARE UV-WIN 6.0
WITH 3D SPECTRA
Now all Labomed, Inc. split and double beam spectrophotometers with our newly developed software called UV-Win 6.0 can be used with Windows XP, Windows 7 and Windows 8. It is capable of testing more applications with its RS-232 and USB connections, and supports the data export of measured results to the PC and then flash drive, when additional data storage is required. One of the new features is that it provides 3-D graphing of the spectral results.
Top of the Page
MONOPROCESSOR BUILT- IN APPLICATION
Photometric Measurement: Measuring transmittance or absorbance at the current wavelength together with K factor calculations..
Spectrum Scan: Carrying out scanning of transmittance or absorbance on the selected wavelength range together with peak-pick module.
- Quantitative Determination: Regression of standard curves and direct determination concentration of samples.
PC WINDOWS APPLICATION SOFTWARE (RS-232 and USB INTERFACE) - Photometric Measurement: Measuring the photometric values at 1-10 wavelengths together with mathematical calculations according to entered quotations.
- Spectrum Scan: Producing Wavelength scans within the operating parameters on samples together with powerful data handling facilities.
- Quantitative Determination: Determination of unknown concentration with methods of 1-3 wavelength quantitation, together with fitting of calibration curve of 1st ~ 4th order.
- Kinetics: Recording curves of changing photometric values of samples against timecourse at the selected wavelengths together with powerful data handling facilities.
- Output: With the Windows clipboard, the measured data and graphics can be copied to other applications software for reports.
Accessories
Top of the Page
|
| ||
|
Technical Specifications
Top of the Page
1) Optical System: | Dual Beam (UVD-2700) and Split Beam (UVD-2800) |
- Wavelength Range: | 190 nm – 1100 nm |
- Spectral Bandwidth: | 1.0 nm (UVS-2700) and 0.5, 1.0, 2.0 and 5.0 nm (4 steps) (UVS-2800) |
- Wavelength Display: | 0.1 nm resolution |
- Stray Light: | ≤0.12%T (220nm NaI, 340nm NaNO2) |
- Wavelength Accuracy: | +0.3nm (with automatic wavelength correction) |
- Wavelength Reproducibility: | +0.2 nm |
2) Photometric System: | Double Beam ratio monitoring system (UVD-2700) The split-beam monitoring ratio system (UVD-2800) |
- Optical System: | The crossed monochromator with the high-resolution, diffraction holographic grating. |
- Photometric Method: | Transmittance, absorbance, energy and concentration |
- Photometric Range: | -0.3~3.0 Abs |
- Photometric Accuracy: | +0.002Abs (0~0.5Abs) +0.004Abs (0.5~1.0Abs) +0.15%T (0~100%T) |
- Photometric Reproducibility: | +0.001Abs (0~0.5Abs) +0.002Abs (0.5~1.0Abs) +0.15%T (0~100%T) |
- Baseline Flatness: | ±0.002 Abs (200-1100nm) |
- Baseline Stability: | 0.001Abs/30 min (2 hours warming up, 2nm Bandwidth at 500nm) |
-Scanning Speed: | 1400nm/min or Selectable |
-Interface Card: | RS-232 |
-Detector: | Dual Silicon photodiodes |
-Photometric Display: | -9999 ---- 9999 |
-Photometric Noise: | ±0.001Abs (500nm, 30 min warmup) |
-Slew rate of Wavelength: | 3600nm/min. |
-Standard Functionality | Photometric, Quantitative, Spectrum and DNA measurements |
3) DNA/RNA Measurement: | |
- Results Printout. | Printing of measured data by using HP Deskjet 600/800 series (optional) |
4) Mainframe: | Compact and standalone spectrophotometer mainframe |
- Light Source: | Socket Deuterium Lamp and Socket Tungsten Halogen Lamp. - Detector: Silicon photodiode |
- Software Support: | UVWin 6.0 |
- Display: | Digital LCD Display |
- Sample Chamber: | Automatic eight-cell sample holder/changer |
- Size: | 22"x16"x10” |
- Weight: | 55 Lb. |
ALSO AVAILABLE
Spectro UV-VIS Dual Beam PC (Model UVS-2800)
Scanning Spectrophotometer UV-VIS
Split Beam 8 Auto Cell
Variable Bandwidth
Bandwidth: 0.5, 1.0, 2.0 and 5 nm.