詳細介紹
一種模擬細胞生長過程中的機械應(yīng)力裝置:美國B-Bridge細胞牽拉儀(STREX)。
共有型號:
ST-140-04
ST-140-10
ST-150
ST-160
ST-190-XY
ST-195
B-Bridge細胞牽拉儀可精準控制施加在細胞上的應(yīng)力級別,使張力腔室中的種子細胞被拉伸或壓縮,更好的模擬了自然動態(tài)生理環(huán)境。ST-190-XY有168個自定義應(yīng)變參數(shù)(8個拉伸/壓縮比 8個頻率),其余皆為64個自定義應(yīng)變參數(shù)(8個拉伸/壓縮比 8個頻率)。
型號:
ST-150
ST-160
ST-190-XY
ST-195
可與顯微鏡聯(lián)用
型號:
ST-140-04
ST-140-10
ST-150
ST-160
ST-195
可單向控制施加在細胞上的應(yīng)力
型號:
ST-190-XY
可沿X軸和Y軸壓縮雙向控制施加在細胞上的應(yīng)力
型號ST-140-04采用4cm2硅膠腔室
型號ST-140-10采用10cm2硅膠腔室
型號ST-150采用4cm2硅膠腔室
型號ST-160采用0.2cm2硅膠腔室
型號ST-190-XY采用10cm2硅膠腔室
型號ST-195采用4cm2硅膠腔室
ST-150
ST-160
ST-190-XY
ST-195
Stretch Chambers
The exceptional physical and chemical properties of the silicone elastomer PDMS (polydimethylsiloxane) create a specially flexible thin-membrane chamber.
Stretch chambers are flexible culture dishes developed for inducing mechanical stimulation on cultured cells.
- High reproducibility: Spring-like PDMS chambers bounce back from stretching and compressing. With their original properties intact. The chambers show good reproducibility in applications which need continuous mechanical stretching over prolonged periods of time.
- Superior transparency: An optically transparent, ultra-thin (100-200 μm) membrane at the well bottom. It not only makes stretch chambers compatible with optical microscopy techniques, but with fluorescence detection and microscopy as well.
Uniformity of direction and force are issues of crucial concern in cell stretching.
Stretching systems and chambers with insufficient properties can cause extraneous stretching on the wrong axis and generate a secondary load in that direction.
Also, these systems may not apply equal stress to all the cells in the chamber. This makes it difficult to accuray gauge the effect of the stretch stimulus across the unevenly treated sample.
The STREX Cell Stretching System is designed to achieve stretching in a single, parallel direction, with only a weak secondary load.
Research has demonstrated that the STREX system enables highly reproducible cyclic stretching over prolonged periods at ratios of 1-20%. (Ref.)
Because the methyl groups align themselves to the surface, the stretch chamber is highly water-repellent, meaning that cells will not adhere without pre-treatment of the chamber.
Thus, the PDMS chamber surface needs to be coated with extracellular matrix to successfully adhere the culture cells. Fibronectin, collagen, gelatin and laminin, among others, can be used for this purpose.
STREX offers standard stretch chambers in two sizes, the 4 cm² and 10cm² models. Specialized versions are also available, including multi-well, gel-stretching, and transwell experiment chambers.
Ref. Naruse. K., Yamada T., Sai X.R., Hamaguchi M., Sokabe M. (1998), Pp125FAK is required for stretch dependent morphological response of endothelial cells. Oncogene,17:455-463.
Stretch Chambers
4cc Chamber
STB-CH-04
Corresponding models:
STB-140-04
STB-150
STB-10-04
Culture area:
2.0 x 2.0 x 1.0 cm
Shop
Real Time Imaging
STB-CH-0.02
Corresponding models:
STB-150W
up to 40x magnification
(In order to see at this magnification the motor must be turned off briefly.)
Culture area:
1.0 x 1.0 x 0.02 cm
Shop
Biaxial Stretch Chamber
STB-CH-04-XY
Corresponding models: STB-190-XY
Culture area:
2.0 x 2.0 x 1.0 cm
Shop
10cc Chamber
STB-CH-10
Corresponding models:
STB-140-10
STB-10-10
Culture area:
3.2 x 3.2 x 1.0 cm
Shop
Three Dimensional Culture
STB-CH4-G
Corresponding models:
STB-140-04
STB-10-04
Culture area:
1.0 x 1.0 x 0.02 cm
Shop
Tissue Samples
STB-CH-0.06
Corresponding models:
STB-140-04
STB-140-10
For Pulmonary Tissue
Culture area:
1.0 x 0.6 x 1.0 cm
STB-CH-4W
Corresponding models:
STB-140-10
STB-10-10
Culture area:
1.5 x 1.5 x 1.0 cm
Shop
STB-CH4-GP
Corresponding models: STB-140-04 STB-10-04
4 microchambers 20 x 20mm
Culture volume: 4cc
Shop
STB-CH-1.5
Corresponding models:
STB-140-04
STB-140-10
For Achilles Tendon
Culture area:
1.5 x 1.0 x 1.5 cm
Shop
Custom chambers available, contact us for details.