黄色视频不卡_午夜福利免费观看在线_亚洲国产精品999在线_欧美绝顶高潮抽搐喷水_久久精品成人免费网站_晚上一个人看的免费电影_国产又色又爽无遮挡免费看_成人国产av品久久久

    1. <dd id="lgp98"></dd>
      • <dd id="lgp98"></dd>
        1. 產(chǎn)品展廳收藏該商鋪

          您好 登錄 注冊

          當(dāng)前位置:
          世聯(lián)博研(北京)科技有限公司>供求商機(jī)>ChannelMAX 100A-ChannelMAX 100A自動(dòng)膜片鉗和雙電極電壓鉗系統(tǒng)
          ChannelMAX 100A-ChannelMAX 100A自動(dòng)膜片鉗和雙電極電壓鉗系統(tǒng)
          返回列表頁
          • ChannelMAX 100A-ChannelMAX 100A自動(dòng)膜片鉗和雙電極電壓鉗系統(tǒng)

          舉報(bào)
          貨物所在地: 北京北京市
          更新時(shí)間: 2024-10-14 21:00:07
          期: 2024年10月14日--2025年4月14日
          已獲點(diǎn)擊: 260
          在線詢價(jià)收藏產(chǎn)品

          (聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝?。?/p>

          產(chǎn)品簡介

          ChannelMAX 包括四個(gè)自動(dòng)操縱器,兩次灌注一個(gè)數(shù)據(jù)采集控制系統(tǒng),和軟件。 您可以使用系統(tǒng)兩個(gè)雙電極電壓鉗實(shí)驗(yàn),或Z多四個(gè)膜片鉗實(shí)驗(yàn)。 這個(gè)系統(tǒng)為高通量實(shí)驗(yàn)提供了Z佳的價(jià)值。
          優(yōu)點(diǎn)
          ?Z多可運(yùn)行四次膜片鉗實(shí)驗(yàn)或兩次
          雙電極電壓鉗實(shí)驗(yàn)同時(shí)進(jìn)行
          - 用這個(gè)新的設(shè)計(jì),系統(tǒng)提高效率,降低設(shè)備成本
          并節(jié)省空間。 實(shí)驗(yàn)變少了勞動(dòng)密集型。
          ?高質(zhì)量的數(shù)據(jù)記錄 - 系統(tǒng)擁有同樣高品質(zhì),低噪音

          詳細(xì)介紹

          ChannelMAX 100A自動(dòng)膜片鉗和雙電極電壓鉗系統(tǒng)

          包括四個(gè)自動(dòng)操縱器兩次灌注一個(gè)數(shù)據(jù)采集控制系統(tǒng),和軟件。 您可以使用系統(tǒng)兩個(gè)雙電極電壓鉗實(shí)驗(yàn),或zui多
          四個(gè)膜片鉗實(shí)驗(yàn)。 這個(gè)系統(tǒng)為高通量實(shí)驗(yàn)提供了*的價(jià)值。
          優(yōu)點(diǎn)
          •zui多可運(yùn)行四次膜片鉗實(shí)驗(yàn)或兩次
          雙電極電壓鉗實(shí)驗(yàn)同時(shí)進(jìn)行
          - 用這個(gè)新的設(shè)計(jì),系統(tǒng)提高效率,降低設(shè)備成本
          并節(jié)省空間。 實(shí)驗(yàn)變少了勞動(dòng)密集型。
          •高質(zhì)量的數(shù)據(jù)記錄 - 系統(tǒng)擁有同樣高品質(zhì),低噪音,低音漂移數(shù)據(jù)采集為PatchMAX 100A系統(tǒng)。
          •*價(jià)值 - 與傳統(tǒng)電生理學(xué)相比該系統(tǒng)更具成本效益

           

            

          ChannelMAX 100A Mini 
          Patch Clamp and Two Electrode Voltage Clamp System



          ChannelMAX 100A MiniKey Features


          A system for both oocyte and cell patch clamp and two-electrode voltage champ

          This patent-pending design is based on the PatchMAX 100A, but it comes with two computer controlled manipulators.  With the additional micromanipulator, the system can do two patch clamp experiments simultaneously, or one two-electrode voltage clamp experiment.  With this new design, the system increases efficiency, decreases equipment cost, and saves space.  As the system is controlled by the computer, the experiment becomes less labor intensive.

          Run two patch clamp experiments simultaneously

          The ChannelMAX 100A Mini comes with two computer controlled manipulators, as a result users can run two patch clamp experiments simultaneously.  Doing two experiments at the same time allows for better decision making while doing experiments.  Single channel activities are random events.  It is difficult to understand what is going on by looking at the channel open and close, especially when you are working on a new channel.  For example, it is hard to distinguish a channel with two open stages from two channels in the same patch.  With two patches that are treated with the same conditions you have more information that could be critical in making the right decisions while working on the precious seals.


          High quality patch clamp

          ChannelMAX 100A Mini with 2 chambersAs in the PatchMAX 100A, the ChannelMAX 100A the patch clamp is noise free and low drift.  The computer controlled system eliminates human errors so the success rate of making gigaohm seals using the ChannelMAX 100A is over 90%.


          Run two independent patch clamp experiments
           
          It is very easy to change the configuration to run two independent experiments.  As shown in the figure on the right, you can easily have two perfusion chambers on the same setup.

          Automated two-electrode voltage clamp

          For the two-electrode voltage, impalement is controlled by computer so no microscope is needed.  When the electrode enters the oocyte, the membrane potential changes and the movement is stopped.  The user can define the membrane potential threshold and delay for the stop after the electrode enters the oocyte.

          Save on equipment cost

          This system is more cost effective than a traditional electrophysiology setup.  In order to reach the same functionality and productivity using a traditional setup, the equipment cost would be much higher, as compared in the table below.  Plus labor cost is additional.  Coming with the lower cost is also better quality. 

           

          Save space

          As the system can be used for both two-electrode voltage clamp and patch clamp, less lab space is required.  You do not need two data acquisition systems.  All the data is on one computer, so it is easy for you to compare.

          AdaptorSwitching between patch clamp and two-electrode voltage clamp is easy

          The system is designed so that it can switch from patch clamp to a two-electrode voltage clamp easily.  With all of the adjustable parts, the system can easily be adapted to different glass electrode lengths and sizes, and different amplifiers. 

          Use with traditional two-electrode voltage clamp experiments

          It is possible to use the ChannelMAX 100A Mini with a traditional two electrode voltage clamp to run two two-electrode voltage clamp experiments simultaneously.

          High efficiency, less labor-intensive

          As the system is automated, it is easy to run experiments in parallel to increase efficiency.  Patch clamp and two-electrode voltage clamp should not be as labor-intensive as before.  Let the equipment do the hard work for you!



          System Specifications

          Major Components
          • Two micro-manipulators, each one includes a motorized linear stage and a manual XY stage
          • One perfusion chamber I and platform
          • One PCI data acquisition board with BNC interface
          • Mechanical error: < ± 0.05 mm
          • Dimension: 8 in x 12 in x 9.5 in
          • Weight: 10 lb
          • Line voltage: 100 VAC to 120 VAC, or 220 VAC to 240 VAC

          Motorized Stage

          • Travel: 28 mm
          • Resolution: 0.05 µm
          • Maximum speed: 4 mm/s
          • Lowest speed: 0.5 µm/s
          • Serial/USB interface

          Manual XY Stage

          • Modular Dovetail Linear Stages
          • Set, lock, and forget; less susceptible to shock and vibration
          • 0.5 in travel

          Data Acquisition Board

          • Sixteen analog inputs, 16-bit, 250 kS/s, Input Impedance: > 10 GΩ in parallel with 100pF
          • Two 16-bit analog outputs, 740 kS/s per channel.  Output impedance: 0.2 Ω
          • 24 digital I/O lines, 32-bit counters; digital triggering
          • Analog input range: ± 10 V
          • Analog output range: ± 10 V

          Perfusion Chamber

          Accepts 1/16" tubin

           

          收藏該商鋪

          登錄 后再收藏

          提示

          您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

          對比框

          產(chǎn)品對比 產(chǎn)品對比 聯(lián)系電話 二維碼 在線交流

          掃一掃訪問手機(jī)商鋪
          86-010-67529703
          在線留言
          苏尼特左旗| 梧州市| 广宁县| 奉新县| 崇左市| 新源县| 营山县| 大城县| 漯河市| 石棉县| 睢宁县| 齐河县| 滨州市| 江津市| 天台县| 丹阳市| 广安市| 保定市| 万盛区| 平果县| 中山市| 黄浦区| 中卫市| 广州市| 江津市| 微山县| 岳阳县| 剑河县| 公安县| 金山区| 西华县| 古田县| 修武县| 汶川县| 河西区| 普安县| 桐乡市| 普定县| 张家口市| 隆回县| 儋州市|