- 一、美國tissuegrowth公司臨床相關(guān)的力學(xué)刺激組織工程生物反應(yīng)器專家,世聯(lián)博研北京科技公司作為美國tissuegrowth在中國大陸**代理商,簽約代理以下產(chǎn)品:
- 1、三維力學(xué)加載細胞組織工程培養(yǎng)系統(tǒng)
- 2、三維軟骨力學(xué)刺激組織工程生物反應(yīng)器
- 3、3D血管組織工程搏動培養(yǎng)系統(tǒng)
- 4、3D肌腱韌帶組織工程力學(xué)培養(yǎng)生物反應(yīng)器
- 5、3D心臟瓣膜組織工程培養(yǎng)系統(tǒng)
- 6、三維骨應(yīng)力刺激組織工程生物反應(yīng)器
- 7、三維皮膚力學(xué)機械刺激組織工程生物反應(yīng)器
- 8、3D灌注培養(yǎng)組織工程生物反應(yīng)器
- 9、3d支架培養(yǎng)組織工程系統(tǒng)
- 10、多樣品三維力學(xué)加載細胞組織組織工程培養(yǎng)系統(tǒng)
世聯(lián)博研(北京)科技有限公司*:咨詢、索取資料!
- 二、世聯(lián)博研北京科技公司還簽約代理美國Flexcell公司細胞拉力、壓力及剪力仿真培養(yǎng)系統(tǒng)
- 是美國Flexcell在中國大陸**代理商,簽約代理以下產(chǎn)品:
- 儀器部分:
- 1、FX-5000C細胞壓力加載系統(tǒng)(flexcell FX5000 Compression system)
- 2、FX-5000T細胞應(yīng)力加載系統(tǒng)(Flexcell FX5000 Tension system)
- 3、Flex Jr. Tension顯微應(yīng)力加載系統(tǒng)(Flex Jr. Tension)
- 4、TissueTrain三維細胞組織培養(yǎng)系統(tǒng)(Flexcell Tissue® Train System)
- 5、STR-4000細胞流體切應(yīng)力系統(tǒng)(Flexcell Fluid Shear Stress Device)
- 6、應(yīng)力/壓力傳導(dǎo)儀(FlexLink® FX-5000TFL/FX-5000CFL Tension or Compression)
- 7、flexcell自動掃描設(shè)備和XyFlEX計算軟件(ScanFlex with XyFlex)
- 8、HiQFlowmate液體控系統(tǒng)(HIQ-4000-A/B/C HiQ Flowmate-Fluid Control System)
- 9、OsciFlow_切應(yīng)力模式控制器
- 10、SFlex_SFlexJr_顯微應(yīng)力加載系一號(StageFlexer StageFlexer Jr. Microscopy Tension Device)
- 11、FlexFlow顯微切應(yīng)力加載設(shè)備二號(StageFlexer StageFlexer Microscopy Tension Device)
- 12、STR-4000C 流體剪切系統(tǒng)W/O型電腦(Streamer Fluid Shear System w/o Computer)
- 13、STR-4000D Streamer Fluid Shear Body Only
- 14、Flexcell 儲壓泵(Pressure Reservoir)
- 15、FlexStop真空隔離閥
- flexcell培養(yǎng)耗材部分:
- 1、TTPlate三維細胞培養(yǎng)板
- 2、BioFlex(flexcell BioFlex培養(yǎng)板)
- 5、UniFlex(flexcell雙向應(yīng)力培養(yǎng)板)
- 6、BioPress壓力加載系統(tǒng)配套使用的BioPress培養(yǎng)板
- 7、細胞培養(yǎng)載片
- 8、圓形TTCircular三維細胞培養(yǎng)板
- 9、HI bioFlex培養(yǎng)板
- 10、SFMembrane_硅膠膜
- Flexcell儀器、配件銷售與租賃
三、世聯(lián)博研北京科技公司還簽約美國ebersmedical 一個簡單的機械性刺激細胞培養(yǎng)系統(tǒng),簽約代理以下產(chǎn)品:
- 1、TC-3 Bioreactor(簡單的機械性刺激細胞培養(yǎng)系統(tǒng))
- A simple mechanical stimulation cell culture system at last!
- The TC-3 Bioreactor has been designed as a simple easy-to-use system suitable for cell culture
- under mechanical loading profiles defined by the user.
- It has been designed and manufactured thinking of the needs of
- researcher working on cell culture under mechanical stimuli.
- The TC-3 combines the features of a traditional testing machine with the particular demands of cell culture,
- with special emphasis on the parts sterilization, easy assembling,
- sample inspection by microscopy techniques and simple manipulation. Also scalability and
- versatility are key features of the TC-3, in which three grips models can be interchanged
- in order to adapt to the features of the testing substrate or scaffold.
- The system is controlled by a simple computer interface which allows defining the most
- common loading profiles which can be applied on the culture substrate.
- 2、TEB1000 flow bioreactor(TEB1000流體生物反應(yīng)器)
- 3、TC-3 mechanical stimulation bioreactor(TC-3機械性刺激生物反應(yīng)器)
- 4、P3D perfusion chambers(灌注細胞培養(yǎng))
- 5、Vascular Chamber(血博灌注細胞培養(yǎng))
四、簽約代理美國B-Bridge細胞牽拉儀(STREX)
美國B-Bridge細胞牽拉儀(STREX)是一種模擬細胞生長過程中的機械應(yīng)力裝置。通過施加細胞應(yīng)力,張力腔室中的種子細胞被拉伸或壓縮。施加在細胞上的機械應(yīng)力更好的模擬了自然動態(tài)生理環(huán)境。STREX可控制施加在細胞上的應(yīng)力級別,部分型號可與顯微鏡聯(lián)用。
ST-140-04
ST-140-10
簡述
CardioGen HeartValve Bioreactor
The DynaGen Series
Watch a video of the CardioGen bioreactor.
The DynaGen® Series bioreactors provide mechanical stimulation to three dimensional tissue engineered constructs to create physiological conditions in-vitro. The CardioGen system imparts pulsatile flow and pressure to a valve or valve-like structure. Applications include the investigation of cell function and differentiation, pharmaceutical benchtop testing, and the seeding and growth of engineered tissues and medical devices.
Chambers
The CardioGen bioreactor chamber accommodates pulsatile and shear stress stimulation for a single valve construct. Standard construct sizes may range from 9 to 21 mm inner diameter and from 50 to 80 mm long. Grip placement can accommodate both pulmonary valves with straight downstream vessels and aortic valves with angled downstream vessels. The modular design facilitates scaffold installation and cell seeding separate from the stimulation system. Multiple ports are available for media access, catheter probe insertion, sample collection, or further instrumentation. The autoclavable chamber has a volume of 430 mL. Additional chamber features include:
Design: | Polycarbonate hinged windows for easy viewing and laser micrometer measurement | ||
Size: | 145mm(5.7”)L x 105mm(4.15”)W x 74mm(2.9”)D | ||
Ports: | 6 |
Grip Options
CardioGen chambers use barbed stainless steel fittings and either sutures or clamps to fix the construct in place. Standard barb sizes range in size from 9 to 21 mm and are interchangeable using a universal connector system.
DynaGen® Stimulator:
The CardioGen bioreactor system includes the 6Vr pulsatile pressure mechanical stimulator. The 6Vr stimulator features a 40N linear motor that is compact, corrosion resistant and incubator compatible. The stimulator employs pressure control to deliver user defined sinusoidal or physiological pressure waveforms to a maximum pressure of 200 mmHg. The 6Vr is integrated with a computer controlled mean flow pump and is capable of low or high-flow configurations. The flow rate of the mean flow pump is automatically altered to maintain the desired mean pressure within the heart valve. The stimulator dimensions are as follows:
Size: | 152mm(6.0”)H x 102mm(4.0”)W x 102mm(4.0”)D | ||
Weight: | 2.1kg (4.6lb) |
GrowthWorks® Software & Control:
A fifth generation design, the GrowthWorks Software and Control platform includes advanced capabilities, such as multiple waveform control, data acquisition and multi-motor operation. The intuitive software runs on a Windows® laptop computer and features a simple user interface. User defined stimulation profiles are controlled by the software and are readily monitored using graphical displays. Integrated data acquisition routines capture and record data at user prescribed intervals. The GrowthWorks Software is configurable for running four stimulators while simultaneously monitoring up to 16 transducers, allowing the researcher maximum flexibility.
The GrowthWorks Control Hardware features an embedded In CPU, integrated data acquisition and integrated motor drives. Communications between the laptop and control hardware is transmitted over a standard network cable. Primary advantages of the TGT Laptop/Controller approach are reduced physical size and easy upgradability. As future Windows versions or higher performance Laptops become available, either can be replaced without any software or controller changes. This ensures the GrowthWorks control system will be an integral part of your research for many years to come.
GrowthWorks Stiffness Measurement & Analysis Software:
The GrowthApps modules provided added capability to GrowthWorks. The addition of the Stiffness Measurement & Adaptive Control Application enables the system to make real-time measurements of the sample stiffness during culture. Described in U.S. Patent 7,410,792 B2 Instrumented bioreactor with material property measurement capability and process-based adjustment for conditioning tissue engineered medical products., the Application measures the mechanical response of the tissue construct as it is being stimulated and conditioned. The stiffness measurements can be used as guidelines for bench marking progress during culturing or for modifying the stimulation profile. Based upon the measured response, the bioreactor system is then capable of altering the stimulation profile. This technology enables researchers to automatically culture the tendon or ligament from initial seeding to an implantation-ready state with minimal operator intervention.
Click here to download a CardioGen Brochure (Adobe PDF 144kb)