您好, 歡迎來到化工儀器網(wǎng)! 登錄| 免費注冊| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海騁利電子科技有限公司>>探頭和附件>> Tektronix CT1泰克示波器高靈敏度電流探頭|泰克探頭CT1
參 考 價 | 面議 |
產(chǎn)品型號Tektronix CT1
品 牌
廠商性質(zhì)代理商
所 在 地深圳市
更新時間:2024-06-22 08:30:57瀏覽次數(shù):624次
聯(lián)系我時,請告知來自 化工儀器網(wǎng)Optical-to-Electrical Converters
Tektronix CT1泰克示波器高靈敏度電流探頭|泰克探頭CT1的產(chǎn)品介紹
在當(dāng)今的電子產(chǎn)品設(shè)計中,精確的電流幅度測量是實現(xiàn)zui高電源功效的關(guān)鍵。 泰克的電流探頭可提供業(yè)界的測量靈敏度,可以測量低至1毫安的電流。這對于精確地測量小電流和頻率分量非常關(guān)鍵。的泰克示波器和電流探頭協(xié)同運行,可以自動將測量范圍擴(kuò)展到數(shù)安培,大大縮短測量設(shè)置時間。
Features & Benefits
Applications
CT6 Current Probe
The CT6 is the newest addition to the Tektronix portfolio of high-frequency current probes. It is designed to meet the needs of high-speed circuit design and test applications which require ultra-high bandwidth, low inductance, and extremely small form factor. The CT6 provides up to 2 GHz bandwidth when used with high-bandwidth oscilloscopes such as the Tektronix TDS694C, TDS794D, and TDS7000 Series oscilloscopes or with other compatible 50 Ω input measuring instruments. Low inductance (<3 nH) assures that the loading effect of the CT6 on the circuit-under-test will be negligible, which is especially important for today's low-amplitude, high-speed circuit designs such as disk drive read/write preamplifiers. The probe is a closed-circuit design which will accept uninsulated wire sized up to 20 gauge. This product is exempt from CE mark by virtue of its 30 V voltage limit.
CT1/CT2. Current Probes with P6041 BNC Probe Cable.
CT1/CT2 Current Probes
The CT1 and CT2 Current Probes are designed for permanent or semi-permanent in-circuit installation. Each probe consists of a current transformer and an interconnecting cable. The current transformers have a small hole through which a current carrying conductor is passed during circuit assembly.
The P6041 Probe Cable provides the connection between the CT1 and CT2 Current Transformers and a BNC oscilloscope input. A 50 Ω termination is required to terminate the cable when connected to a high-impedance (1 MΩ) oscilloscope input. One probe cable can be used to monitor several current transformers that have been wired into a circuit.
MINIATURE CONSTRUCTION
The CT1 and CT2 detachable cable design enables one or more probes to be located on circuit boards or in other limited space areas.
The CT6 offers the smallest form factor available, for measurement on ever-shrinking circuit boards and components. It is designed for temporary installation and does not incorporate removable cables, as the CT1 and CT2 do.
EXTENDIBLE PROBE LENGTH
Specified rise time and bandwidth are obtained when using the probe cables provided: The P6041 cable used with the CT1 and CT2 is 42 inches nominal. If additional length is required, the cables can be extended by using high-quality 50 Ω cable and suitable interface connectors. (Also see Special Probe Cables, Optional Accessories.) Long cables may degrade high-frequency response.
HIGH SENSITIVITY
The CT1 and CT6 provide an output of 5 mV for each milliamp of input current when terminated in 50 Ω. The CT2 provides 1 mV per milliamp when terminated in 50 Ω.
TYPICAL SYSTEMS
The CT1, CT2, and CT6 high-frequency current transformers are dynamic (i.e., non-DC) current measuring devices. They are typically used in conjunction with compatible high-bandwidth oscilloscopes and other instruments to observe and/or record high-frequency current waveforms. The CT1, CT2, and CT6 normally operate directly into 50 Ω scopes and other measuring device inputs.
The CT1 or CT2 can be used with 1 MΩ input systems; use the P6041 probe cable and terminate the output with a 50 Ω feed-through termination (see Optional Accessories).
In all cases, the CT1, CT2, and CT6 must work into 50 Ωs to obtain specified performance and sensitivity.
Typical Measurement Applications
DIFFERENTIAL CURRENT MEASUREMENTS
Most true-differential voltage amplifiers have a maximum bandwidth of about 100 MHz. The CT1 or CT6 can make differential current measurements to 1 GHz and 2 GHz, respectively, by passing two wires carrying opposing currents through the same core. The displayed result is the difference current. The CT2 can perform the same function to 200 MHz.
In all cases, Derating with Frequency and Amp-second Product (Current-time Product) guidelines should not be exceeded. (See Characteristics.)
SINGLE-SHOT AND LOW REP-RATE PULSE MEASUREMENTS
These common measurements are easy to make with the CT1, CT2, or CT6 provided that your signal fits within the Max Pulse Current and Amp-second Product (Current-time Product) guidelines for the specific current probe characteristics.
For example, the CT2 is rated at 36 A peak, with an Amp-second Product of 50 × 10-6 seconds (50 Amp-microseconds), therefore the CT2 can safely handle a 36 A peak pulse with a maximum width of 1.39 microseconds or lower amplitude pulses for longer pulse widths. The CT1, CT2, and CT6 all have low-frequency roll-off characteristics. Low-frequency "droop" will exhibit itself when the pulse width approaches the L/R time constant of the specific transformer.
PROPAGATION DELAY MEASUREMENTS
Two CT1 or CT2 Current Transformers with matching probe cables can be used to measure propagation delay (transit time) between the input and output currents of high-frequency devices. The probe outputs are connected to the inputs of dual-channel real-time or sampling scopes.
Verification of any Probe/Cable/Scope System mismatch can be obtained by passing the same signal current through both probes and observing total system delay difference, if any.
如您想了解更多示波器相關(guān)知識,或是想試用 示波器 ,請與深圳市邦亞電子科技有限公司客服。如您想定期收到我司活動及*,請寫郵件告知我司。
更多“邦亞電子”優(yōu)勢產(chǎn)品:
溫度校準(zhǔn)器、數(shù)據(jù)采集器、安規(guī)測試儀、功率計、示波器、電子負(fù)載、電源、過程校準(zhǔn)器、LCR數(shù)字電橋、
電信號校準(zhǔn)器、壓力校準(zhǔn)器、毫安回路校準(zhǔn)器、電壓電流校準(zhǔn)器、特殊應(yīng)用儀器、萬用表、數(shù)據(jù)采集器
請輸入賬號
請輸入密碼
請輸驗證碼
以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。
溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。