供貨周期 | 現(xiàn)貨 | 規(guī)格 | 4.1mmx250mm 10um |
---|---|---|---|
貨號(hào) | 79433/79448 | 應(yīng)用領(lǐng)域 | 環(huán)保,食品,生物產(chǎn)業(yè),農(nóng)業(yè) |
產(chǎn)品簡(jiǎn)介
詳細(xì)介紹
Hamilton PRP-X100 Hamilton食品總砷無(wú)機(jī)砷檢測(cè)陰離子液相色譜柱79433/79448
Hamilton PRP-X100 聚合物 HPLC 色譜柱用于分離離子色譜中的陰離子
Hamilton PRP-X100 HPLC 色譜柱
Hamilton PRP-X100 HPLC Column
10 μm particle size, L × I.D. 25 cm × 4.1 mm, stainless steel hardware
application(s) | HPLC: suitable |
L × I.D. | 25 cm × 4.1 mm |
matrix | PS-DVB particle platform |
matrix active group | ammonium ion, quaternary phase |
particle size | 10 μm |
pore size | 100 ? |
separation technique | anion exchange |
產(chǎn)品各項(xiàng)參數(shù)描述:
Stationary Phase | PRP-X100 |
Mode | Anion Exchange |
Packing Material Type | PSDVB/Trimethylammonium |
Particle Size | 10 μm |
Pore Size | 100 ? |
Format | Column |
Hardware Inner Diameter | 4.1 mm |
Hardware Length | 250 mm |
Hardware Material | Stainless Steel |
Max. Pressure (bar g) | 5,000 psi |
Exchange Capacity | 0.19 meq/gm |
Exchange Capacity/Col | 0.304 meq/column |
Mob-ile Phase Limits | pH 1-13. 0-100% aqueous, organic modifier |
Buffer Strength | 0.0-0.5N |
Temp Limits | pH 179 560C pH 813 530C |
Restoration | Pump approximately 50 mL of methanol with 1% 6 N nitric acid. |
Compound Classification | Organic/Inorganic Anions |
UOM | 1 EACH |
應(yīng)用:無(wú)機(jī)和有機(jī)陰離子的分離和純化
孔徑:100 ?
pH穩(wěn)定范圍:pH 1-13
可輕松分離8種常見(jiàn)離子
可分離自來(lái)水中氟
使用0-100%的有機(jī)溶劑進(jìn)行疏水性陰離子的洗脫或清洗柱子
使用電導(dǎo)率或UV檢測(cè)器
3種粒子尺寸:5/10/12-20 μm
8種柱子的直徑:1.0-50.8 mm
2種柱子材料:316不銹鋼和PEEK
分析柱和制備/半制備保護(hù)柱
分離效果:
1. 常見(jiàn)陰離子(氟、氯、溴、碘)
2. 非直接UV檢測(cè)器檢測(cè)的陰離子
3. EDTA
4. 有機(jī)酸(甲酸、fu乙酸、膦酸、1111)
5. Germall 115
6. 溴酸鹽和其它陰離子
7. 硫酸鹽和亞硫酸鹽
8. 磷酸鹽和磷酸
9. 氯酸鹽
訂貨信息:
訂貨號(hào) | 規(guī)格描述 | 柱管材質(zhì) | ||
79852 | PRP-X100, 5um, 2.1x150mm | PEEK | ||
79190 | PRP-X100, 5um, 2.1x250mm | S S | ||
79810 | PRP-X100, 5um, 4.1x50mm | S S | ||
79538 | PRP-X100, 5um, 4.1x100mm | S S | ||
79812 | PRP-X100, 5um, 4.1x150mm | S S | ||
79174 | PRP-X100, 5um, 4.6x150mm | PEEK | ||
79181 | PRP-X100, 5um, 4.6x250mm | PEEK | ||
79421 | PRP-X100, 10um,2.1x150mm | S S | ||
79346 | PRP-X100, 10um,2.1x250mm | S S | ||
79365 | PRP-X100, 10um, 4.1x50mm | S S | ||
79439 | PRP-X100, 10um, 4.1x100mm | S S | ||
79434 | PRP-X100, 10um, 4.1x150mm | S S | ||
79433 | PRP-X100, 10um, 4.1x250mm | S S | ||
79354 | PRP-X100, 10um, 4.6x150mm | PEEK | ||
79455 | PRP-X100, 10um, 4.6x250mm | PEEK | ||
79353 | PRP-X100, 12-20um, 21.2x250mm | S S | ||
79448 | Guard column Starter Kit(1 holder,2 cartridges) | S S | ||
79446 | Replacement Cartridges(5/pk) | S S | ||
79383 | Guard column Starter Kit(1 holder,2 cartridges) | PEEK | ||
79385 | Replacement Cartridges(5/pk) | PEEK |
不銹鋼保護(hù)柱芯的尺寸: 2.3x20mm, PEEK保護(hù)柱芯的尺寸: 3.0x8.0mm
保護(hù)柱芯(貨號(hào)79446,5只/包)
保護(hù)柱套裝(1柱套2柱芯,貨號(hào)79448)
···································································
常見(jiàn)以下幾種情況:色譜峰拖尾、色譜峰分裂、色譜峰擴(kuò)展,許多色譜峰峰形問(wèn)題都是復(fù)合型問(wèn)題, 造成色譜峰擴(kuò)展和柱效降低;色譜峰擴(kuò)展和拖尾或拖尾隨保留加劇。從以下幾個(gè)方面色譜柱問(wèn)題、溶劑效應(yīng)、進(jìn)樣量(過(guò)載)、樣品的特性、柱外效應(yīng)來(lái)分析。
1、色譜柱問(wèn)題
污物在柱進(jìn)口處積聚-強(qiáng)溶劑沖洗柱子
二次保留效應(yīng)-加入掃尾劑,10mM的TEA
重金屬污染-使用高純硅膠基質(zhì)色譜柱
對(duì)于難溶解的物質(zhì):小體積強(qiáng)溶劑溶解以后用MP稀釋?zhuān)瑨呶矂?0mM的TEA(B性化合物),醋酸胺(A性化合物)不加TEA 10mM的TEA
ASB C18,4.6×150mm,5µm,85% 25mM NaH2Na,15%ACN 1mL/min, 35℃
硅膠純度
初始的硅膠基質(zhì),酸洗后的硅膠基質(zhì),流動(dòng)相:20mM三11因強(qiáng)調(diào)分析速度而發(fā)展出短柱,柱長(zhǎng)3~10cm,填料粒徑2~3µm。為提高分析靈敏度,與質(zhì)譜(MS)聯(lián)接,而發(fā)展出窄徑柱、毛細(xì)管柱和內(nèi)徑小于0.2mm的微徑柱(microbore)。細(xì)管徑柱的優(yōu)點(diǎn)是:①節(jié)省流動(dòng)相;②靈敏度增加;③樣品量少;④能使用長(zhǎng)柱達(dá)到高分離度;⑤容易控制柱溫;⑥易于實(shí)現(xiàn)LC-MS聯(lián)用。
但由于柱體積越來(lái)越小,柱外效應(yīng)的影響就更加顯著,需要更小池體積的檢測(cè)器(甚至采用柱上檢測(cè)),更小死體積的柱接頭和連接部件。配套使用的設(shè)備應(yīng)具備如下性能:能精密輸出1~100µl/min的低流量,進(jìn)樣閥能準(zhǔn)確、重復(fù)地進(jìn)樣微小體積的樣品。且因上樣量小,要求高靈敏度的檢測(cè)器,電化學(xué)檢測(cè)器和質(zhì)譜儀在這方面具有突出優(yōu)點(diǎn)。
采用316不銹鋼或者PEEK為柱材料;
可用于分析,半制備/制備色譜柱及其保護(hù)柱;
粒徑3,5,7,10,12-20微米等多種選擇;
柱內(nèi)徑從1-101毫米;
聚合物基質(zhì)填充原料
穩(wěn)定的 pH 范圍 1-13
*的壓力穩(wěn)定性
柱壽命長(zhǎng)
用于生物高分子分析的 300A 色譜柱
在選擇色譜柱之前,先多了解自己的樣品和雜質(zhì),他們的類(lèi)型結(jié)構(gòu)、極性、酸堿性、分子量大小等等,
1.樣品是極性的且弱酸性的;就可以選擇C18在100%酸性水溶液條件下檢測(cè),即要選擇承受100%純水且對(duì)極性化合物保留很好的色譜柱
2. 如果樣品極性太強(qiáng),或酸性太強(qiáng);可以選擇CN,NH2,或硅膠柱,HILIC(親水色譜),也有使用C18+強(qiáng)陰離子對(duì)試劑或強(qiáng)陰離子交換色譜柱(缺點(diǎn)是離子對(duì)試劑平衡時(shí)間長(zhǎng),對(duì)流動(dòng)相pH要求比較精密,否 則很難重復(fù)實(shí)驗(yàn),另外離子對(duì)試劑很難洗下來(lái),基本上用了離子對(duì)的色譜柱就不能再用于其它實(shí)驗(yàn))
3. 若樣品是堿性的;可選擇高純硅膠柱(高純硅膠缺少金屬雜質(zhì),且硅膠端基封尾)或一些經(jīng)過(guò)修飾的C18柱(如極性嵌入技術(shù)或堿去活技術(shù)等),他們都會(huì)減少堿性化合物的拖尾,一般會(huì)選擇中性或偏堿的條件下做,因?yàn)檫@樣可增加堿性樣品的保留
4.如果堿性化合物的極性太強(qiáng),或堿性太強(qiáng);可以選擇寬pH的C18色譜柱在高pH值檢測(cè)(優(yōu)點(diǎn)是方法開(kāi)發(fā)簡(jiǎn)單,缺點(diǎn)是目前實(shí) 現(xiàn)這一技術(shù)的色譜柱品牌比較少,價(jià)格也高)或者選用HILIC色譜柱(硅膠柱在反相條件下使用,這也是很經(jīng)典的檢測(cè)堿性樣品的方法)選擇強(qiáng)離子交換柱(缺點(diǎn) 是不能用來(lái)分析其它樣品,對(duì)流動(dòng)相pH要求比較精密,否則很難重復(fù)實(shí)驗(yàn))也有使用C18+強(qiáng)陰離子對(duì)試劑或強(qiáng)陰離子交換色譜柱。