產(chǎn)品簡介
詳細介紹
Acclaim Carbonyl LC Column
High Resolution HPLC of Aldehyde and Ketone Contaminants
The Thermo Scientific Acclaim* Carbonyl C18 HPLC columns are designed specifically for superior resolution and high-throughput separation for DNPH derivatives of aldehydes and ketones regulated by the U.S. Environmental Protection Agency (EPA) in methods such as EPA 554, EPA 8315, EPA 1667, EPA TO-11, and by the California Environmental Protection Agency Air Resources Board in method CARB 1004.
- High efficiency for UHPLC performance
- Rugged columns with good lot-to-lot reproducibility
- Proven robust methods
Carbonyl compounds, including low molecular weight aldehydes and ketones, cause environmental and health concerns. Because of their highly volatile and reactive nature, carbonyl compounds are often converted to the dinitrophenylhydrazine (DNPH) derivatives prior to analysis. The Acclaim Carbonyl C18 columns are high-performance reversed-phase columns specifically designed for high throughput and baseline separation of thirteen DNPH derivatives of aldehydes and ketones regulated by CARB Method 1004. In addition, the same chromatographic method can be applied directly to other regulatory methods such as EPA 554, EPA 8315, and EPA TO-11.
The columns are available in three particle sizes: 2.2, 3 and 5?m. Smaller particle sizes provide high peak efficiency for fast analysis. Small internal diameter (i.d.) columns (e.g., 2.1 and 3.0 mm) consume less solvents and produce less chemical waste. For high-throughput application, the 2.1 × 100 mm column format combined with high linear velocity should be considered. When high resolution power is desired, a longer column (2.1 × 150 mm) can be used at an optimal linear velocity to achieve even better resolution.
技術參數(shù):
Acclaim Carbonyl C18 Column Specifications | |
---|---|
Column chemistry | Proprietary alkyl group |
Operating pressure limit (recommended) | 800 bar for 2.1 x 150mm; 2.2?m 600 bar for 2.1 x 150mm; 3.0 ?m 600 bar for 2.1 x 100mm 700 bar for 3.0 x 100mm 600 bar for 3.0 x 150mm 800 bar for 3.0 x 250mm |
Operating pH range (recommended) | 2.5–7.5 |
Operating flow rate range (recommended) | 0.4–1.4 mL/min for 3.0 mm i.d. formats 0.25–0.75 mL/min for 2.1 mm i.d. formats |
Operating temperature (recommended) | 25 -35 °C |
訂購信息:
Analytical Columns | |
---|---|
Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 100mm) | 077972 |
Acclaim Carbonyl RSLC Analytical,2.2?m (2.1 x 150mm) | 077973 |
Acclaim Carbonyl RSLC Analytical,2.2?m (3.0 x 100mm) | 077974 |
Acclaim Carbonyl C18 Column 3?m Analytical (2.1 x 150 mm) | 079011 |
Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 150 mm) | 079010 |
Acclaim Carbonyl C18 Column 3?m Analytical (3.0 x 250 mm | 079009 |
Acclaim Carbonyl C18 Column 5?m Analytical (4.6 x 150 mm) | 079008 |
Guard Columns | |
---|---|
Acclaim Carbonyl C18 Column 5?m Guard (2.1 x 10 mm), 2/pk | 079012 |
Acclaim Carbonyl C18 Column 5?m Guard (3.0 x 10 mm) , 2/pk | 079013 |
Acclaim Carbonyl C18 Column 5?m Guard (4.6 x 10 mm), 2/pk | 079014 |