詳細介紹
優(yōu)勢產(chǎn)品/德國進口BURKERT寶德傳感器
:
手 機:
電 話:
傳 真:021-(請備注收)
公司地址:上海市中江路889曹楊商務大廈1501-1502
上海維特銳實業(yè)發(fā)展有限公司
*,發(fā)表隨貨,優(yōu)勢供應眾多歐美產(chǎn)品,本公司德國、美國設有公司,13年老公司信譽保證!
型如下:788350 SET8-7800-0185PPFF-00-00-0-000/00-0
788351 SET8-7800-0480PPFF-00-00-0-000/00-0
788590 2508-00-B-PO-3-1-BCS * JW03
788645 1045-AE02-S-1/10-042-STV-SAUERST.
789157 2508-00-B-PO-3-1-BCS * JW09
789249 2508-00-B-PO-3-3-BCS * JW12
789264 2507-00-B-PO-3-1-BCS * JC35+JG20+JW12
789298 KOMP-430-0000-0000-000-00-0789298
789299 KOMP-005-0000-0000-000-00-0789299
789300 KOMP-430-0000-0000-000-00-0789300
789302 3230-2-0-15,0-FF-PV-KM25-00E1
789397 TKU003-2-VA-EE-20,0-GM86-GM86-063
789439 TKU002-2-VA-EE-11,0-GM82-GM82-063
789443 TKU002-2-VA-EE-25,0-GM87-GM87-063
789444 TKU002-2-VA-EE-32,0-GM88-GM88-063
789445 TKU002-2-VA-EE-40,0-GM89-GM89-063
789446 TKU003-2-VA-EE-11,0-GM82-GM82-063
789447 TKU003-2-VA-EE-12,0-GM83-GM83-063
789448 TKU003-2-VA-EE-12,0-GM84-GM84-063
789449 TKU003-2-VA-EE-15,0-GM85-GM85-063
789450 TKU003-2-VA-EE-25,0-GM87-GM87-063
789451 TKU003-2-VA-EE-32,0-GM88-GM88-063
789452 TKU003-2-VA-EE-40,0-GM89-GM89-063
789453 TKU001-3-VA-EE-08,0-GM82-GM82-063
優(yōu)勢產(chǎn)品/德國進口BURKERT寶德傳感器
:
手 機:
電 話:
傳 真:021-(請備注收)
公司地址:上海市中江路889曹楊商務大廈1501-1502
上海維特銳實業(yè)發(fā)展有限公司
*,發(fā)表隨貨,優(yōu)勢供應眾多歐美產(chǎn)品,本公司德國、美國設有公司,13年老公司信譽保證!
環(huán)境溫度溫度限制可能取決于傳感器。請
請參考相應的指導手冊或數(shù)據(jù)表
真正的工會,套管和外螺紋
流量變送器
?通用接頭插入傳感器,變送器,
在純粹的,攻擊性或contamined液體批量控制器
?大范圍過程連接: DN 06 ?400
在聚氯乙烯,聚丙烯,聚偏氟乙烯,聚乙烯,不銹鋼,黃銅
?可用于電子
- 指示,監(jiān)控,傳輸
- 開/關控制,批量控制
媒體中的數(shù)據(jù)
流體溫度
( 160 °Czui大。 )
溫度限制可能取決于傳感器。請
請參考相應的指導手冊或數(shù)據(jù)表
壓力限制可能取決于傳感器。請參閱
適當?shù)氖褂谜f明書或數(shù)據(jù)表的更多
1 )擬合和傳感器之間的組合,有時僅限于一些DN (參見圖: S020結(jié)合
下頁上的傳感器)Minimum straight upstream and downstream distances must be observed. According to the pipe’s design, necessary distances can be bigger or use a
flow conditioner to obtain the best accuracy. For more information, please refer to EN ISO 5167-1.
EN ISO 5167-1 prescribes the straight inlet and outlet distances that must be complied with when installing fittings in pipe lines in order to achieve
calm flow conditions. The most important layouts that could lead to turbulence in the flow are shown below, together with the associated prescribed
minimum inlet and outlet distances. These ensure calm, problem-free measurement conditions at the measurement point.
The flow rate sensor can be installed in either horizontal or vertical pipes.
Analysis measurement:
condition and enable the customer to calibrate the
unit without stopping the whole process or to use the special designed measuring chamber.
The specially designed measuring chamber enables to install all pH-, ORP-, conductivitytransmitters
or electrodes in all pipe systems, either directly in the main stream or in a
by-pass line. Additionally it enables to keep the electrode always wet and isolates it easily
from the main stream for calibration purposes.
:
手 機:
電 話:
傳 真:021-(請備注收)
公司地址:上海市中江路889曹楊商務大廈1501-1502
上海維特銳實業(yè)發(fā)展有限公司
*,發(fā)表隨貨,優(yōu)勢供應眾多歐美產(chǎn)品,本公司德國、美國設有公司,13年老公司信譽保證!