Dionex IonPac CS14陽(yáng)離子交換柱 044123
用途和特點(diǎn):
IonPac CS14陽(yáng)離子交換分離柱用于等度,快速分離脂肪胺,烷醇胺,NH4+,堿金屬和堿土金屬;甲基磺酸或鹽酸作淋洗液.有機(jī)溶劑可匹配性利于控制陽(yáng)離子交換選擇性,增強(qiáng)樣品溶解度,以及方便柱子清洗。樣品基體包括:?jiǎn)徇蛞掖及诽幚磉^(guò)的電廠用水;化學(xué)添加劑;化學(xué)生產(chǎn)過(guò)程溶液;電鍍槽中的洗滌液;廢水;土壤萃取物以及溶劑等。
Dionex IonPac CS14陽(yáng)離子交換柱 044123
訂貨信息:
Dionex IonPac CS14陽(yáng)離子交換柱
分析柱 | |
IonPac CS14 Analytical Column (2 x 250 mm) | 044121 |
IonPac CS14 Analytical Column (4 x 250 mm) | 044123 |
保護(hù)柱 | |
IonPac CG14 Guard Column (2 x 50 mm) | 044122 |
IonPac CG14 Guard Column (4 x 50 mm) | 044124 |
Medium Low-Capacity Column for Aliphatic and Aromatic Amines and Polyamines
The IonPac? CS14 is a medium low-capacity carboxylate-functionalized cation-exchange column for the determination of aliphatic, aromatic, and polyvalent amines. Sample matrices include environmental waters; power plant waters treated with ammonium, morpholine or ethanolamine; chemical additives; chemical process solutions; scrubber solutions; plating baths; industrial solvents; and wastewater.
For amine separations, including aliphatic amines, aromatic amines, and polyamines
For hydrophobic and polyvalent amines
For polar amines including alkanolamines and alkylamines
For moderately hydrophobic amines
Compatible with organic solvents
The CS14 column can be used with isocratic or gradient methanesulfonic acid or sulfuric acid eluents to resolve a variety of amines from the Group I and II cations. Solvent and elevated temperature may be required for efficient elution of hydrophobic amines. Use the Cation Self-Regenerating Suppressor (CSRS? 300) with the CS14 column.
The CS18 and CS17 are recommended replacement columns for most CS14 applications. The CS17 is recommended replacement column for hydrophobic and polyvalent amines, including biogenic amines and diamines. The CS18 is recommended for polar amines, including alkanolamines and methylamines; and moderately hydrophobic and polyvalent amines, including biogenic amines and alkyldiamines.
IonPac CS14 Cation-Exchange Column Specifications | |
---|---|
Dimensions | IonPac CS14 Analytical Column: 2 × 250 mm and 4 × 250 mm IonPac CG14 Guard Column: 2 × 50 mm and 4 × 50 mm |
Maximum operating pressure | 4000 psi (27.5 MPa) |
Mobile phase compatibility | Acidic eluents; 0–100% HPLC solvents, except TFH 0-20% |
Substrate characteristics | Bead Diameter: 8 μm Cross-Linking (%DVB): 55% |
Functional group characteristics | Ion-Exchange Group: Carboxylic acid Surface Characteristics: Moderately hydrophilic |
Capacity | 1300 μeq (4 × 250 mm analytical column) 325 μeq (2 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |