詳細(xì)介紹
RX-360SH自動(dòng)熒光定硫儀
X-360SH 是按“能量色散X射線熒光光譜法(EDXRF) ”測(cè)定石油產(chǎn)品硫含量的儀器??赏ㄓ糜谲囉闷?,柴油,原油,石腦油,渣油,潤(rùn)滑油基礎(chǔ)油,液壓油,噴氣燃料和其他餾分油在內(nèi)的碳?xì)浠衔镏械牧蚝繙y(cè)定。適用于ISO 8754 ,ASTM D4294-03.,GB/T 17040的標(biāo)準(zhǔn)。測(cè)試過程簡(jiǎn)單高效,試驗(yàn)結(jié)果準(zhǔn)確和重復(fù)性良好,是一種經(jīng)濟(jì)的無損測(cè)試.方法。
HIGH PRECISION: Digital pulse height analysis is automatically carried out at each measurement to adjust the system. This innovative system design has further improved the precision.
高精度:RX-350是一種可移動(dòng)的高精度硫分析儀,體積小巧,便于搬運(yùn),原來必須在實(shí)驗(yàn)室是進(jìn)行的硫分分析現(xiàn)在可通過直接在現(xiàn)場(chǎng)提取試樣,立即得到高精度的分析結(jié)果。分析場(chǎng)所有了飛躍性的擴(kuò)大。
WIDE RANGE OF SAMPLES: Patented “Diamond Parameter Method” accuray compensates for measurement error caused by different carbon/hydrogen(C/H) ratio of individual sample. This state-of-art technology enabled measurement of wide range of samples of different C/H ratios with uncompromising precision.
測(cè)試范圍廣:*的技術(shù) “Diamond Parameter Method”,無論是輕油,原油,重油。從低濃度到高濃度,均能在短時(shí)間內(nèi)通過簡(jiǎn)單的操作,高精度地測(cè)出硫分值。對(duì)于不同的碳?xì)浠衔铮?/span>C/H)也能自動(dòng)補(bǔ)正
AMBIENT TEMPERATURE AND BAROMETRIC PRESSURE COMPENSATION: Compensation for ambient temperature and barometric pressure are made automatically to drastically minimize the drift. 對(duì)于環(huán)境的影響,可通過氣壓補(bǔ)正,溫度補(bǔ)正進(jìn)行自動(dòng)調(diào)整。
RX-360SH自動(dòng)熒光定硫儀
AUTOMATIC CALIBRATION: Set certified calibration standards and start automatic calibration program to carry out automatic calibration. Either multiple point calibration at up to 10 points or two points calibration starts.
用標(biāo)準(zhǔn)樣品校正時(shí),可自動(dòng)進(jìn)行多點(diǎn)(zui多到10點(diǎn))的補(bǔ)正。
EASY OPERATION: Minimum numbers of membrane switches are located on the operation panel along with an LCD for easy dialogue type operation.
整個(gè)試驗(yàn)過程和采集的數(shù)據(jù),可在LCD 上清晰顯示。
COMPACT DESIGN/2-WAY POWER SOURCE: Compact design unit with carrying handle and 2-way power
RX-350是一種可移動(dòng)型的高精度硫分析儀,體積小巧,便于搬運(yùn),可使用2種方式供電。可通過直接在現(xiàn)場(chǎng)提取試樣,立即得到高精度的分析結(jié)果
source (100-240VAC*1 or 12VDC battery*2) allows such applications as spot-checking in the field.
*1: When used with the provided AC Adapter (100-240V AC 交流電源)
*2: When used with optional 12VDC cord with lighter plug (車載12 V 蓄電池直流電)
LOWER RUNNING COST: The Teflon sample cell is permanent and used with a small piece of disposable Mylar film. The only other consumable is the printing paper, making the running cost at minimal.
運(yùn)行維護(hù)成本低:試驗(yàn)儀器所有的配件中只有“測(cè)試膜”和“打印紙”是易耗品,日常使用和運(yùn)行維護(hù)成本很低。
TYPE:
Total sulfur analyzer for petroleum products by energy-dispersive X-ray fluorescence method
用非色散X射線熒光光譜分析法測(cè)定石油產(chǎn)品中硫含量
CONFORMING STANDARDS: (適用標(biāo)準(zhǔn))
ISO 8754, ASTM D4294-03, GB/T 17040 etc.
NUMBER OF TEST:
One(1) (單樣品測(cè)試)
SAMPLE VOLUME: (樣品需求)
3-5ml (每次測(cè)試只需要3-5ml)
MEASURING RANGE: (硫含量測(cè)試范圍)
0-6.00wt%
REPEATABILITY: (Typical) 結(jié)果重復(fù)性
Range(范圍) | Std Deviation(標(biāo)準(zhǔn)誤差) | Measuring Time(測(cè)試計(jì)數(shù)) |
0.008wt%max | 5ppm | 300sec x 3times(300秒測(cè)試3次) |
0.05wt%max | 10ppm | 100sec x 3times |
0.05-0.50wt% | 20ppm | 100sec x 3times |
0.51-1.50wt% | 30ppm | 100sec x 3times |
1.51-2.00wt% | 50ppm | 100sec x 3times |
2.01-4.00wt% | 100ppm | 100sec x 3times |
4.01-6.00wt% | 200ppm | 100sec x 3times |
C/H RATIO COMPENSATION: (C/H補(bǔ)正誤差)
Automatic with 0.003wt% max of compensation error when a 1wt% sample is tested.
MEASURING TIME: (測(cè)試方式)
10-300sec with a 10sec increment. 1-99 times. (測(cè)試時(shí)間10-300秒,每10秒為一單位設(shè)定,可設(shè)定重復(fù)測(cè)試 1-99 次)
CALIBRATION: (儀器標(biāo)定方式)
*Automatic two point calibration 自動(dòng)2點(diǎn)標(biāo)定
*Manual two point calibration 手工2點(diǎn)標(biāo)定
*Automatic multiple-point calibration(up to 10 points) 自動(dòng)多點(diǎn)標(biāo)定(zui多10點(diǎn))
*Manual multiple-point calibration(up to 10 points) 手工多點(diǎn)標(biāo)定(zui多10點(diǎn))
X-RAY SOURCE: (x射線源功率)
X-ray tube operated at 7kV-0.15mA
SAMPLE CUP: 樣品杯
2-piece Teflon cup with disposable Mylar film(2個(gè)聚四氟乙烯樣品底座+一次性(Mylar)分子薄膜)
PRINTER: (打?。?/span>
Built-in impact dot matrix printer (W57mm) (內(nèi)置點(diǎn)式打印機(jī),紙寬57mm)
DISPLAY: (顯示屏)
LCD (20 characters x 4 lines) LCD可顯示20字符,4行
X-RAY LEAKAGE: (x射線源外散)
0.6 micro Sv/Hr or less on instrument surface (經(jīng)測(cè)試,儀器表面小于0.6 micro Sv/Hr)
DATA OUTPUT: (數(shù)據(jù)輸出)
RS-232C 1 channel (標(biāo)準(zhǔn)RS-232C接口,1)
OPARATING TEMPERATURE/HUMIDITY: (環(huán)境要求)
10-30℃ with a temperature drift within 10oC in a day. RH to be within 80%.
室溫10~30℃(一天內(nèi)的溫差變化在10℃以下) / 濕度80‰ RH以下
POWER SUPPLY: (電源需求)
DC12V (with the provided AC Adapter or optional 12VDC cord with lighter plug)
外置DC 12V(直流)電源(帶交流電源適配器或車載電源適配器)
SAFETY: (安全防護(hù))
Interlock mechanism against accidental X-ray leakage (雙重保險(xiǎn)設(shè)計(jì),有效避免 x射線泄露)
DIMENSIONS/WEIGHT: 尺寸/重量
(測(cè)試部)Test head: 420mmW x 350mmD x140mmH/11kg
(電源部)AC Adapter: 50mmW x 115mmD x 25mmH/0.25kg
?STANDARD ACCESSORIES: (標(biāo)準(zhǔn)附件)
1.AC Adapter 交流電源適配器 | 1 |
2.Teflon sample cells (5pcs/box) 樣品杯組(5個(gè)/組) | 1組 |
3.Sample cell assembling jig 樣品杯組裝工具 | 1 |
4.Sample cell disassembling jig 樣品杯分解工具 | 1 |
5.Sample cell stand 樣品杯底座 | 1 |
6.Mylar film (200mm x 1,000m) 樣品膜(200mmX1,000米) | 1 |
7.Printer roll paper 打印紙 | 3 |
8.Spare Printer ink ribbon 備用打印機(jī)色帶 | 1 |