產(chǎn)品簡介
詳細(xì)介紹
temperature and humidity chamber feature specification |
model | th-g type | th-i type | |
capacity | 180l, 300l, 408l, 800l, 1000l | ||
control system | bdbc2-fcs(balanced dehumidifying and bath cooling fuzzy control system) | ||
controller | touch screen type 6" b/w monitorlocal controller(fixed-command control) | touch screen type 6" b/w monitor,program controller | |
sensor | temperature | pt100 | |
humidity | electronic sensor(free of drying a wet pack and good response time) | ||
temperature | range | -40"c ~ 150"c | -40"c ~ 150"c |
program control | -35"c ~ 150"c | -35"c ~ 150"c | |
accuracy | ±0.3"c | ||
stability | ±0.3"c (included off-set function) | ||
humidity | range | 35 ~ 80 %rh at 10"c30~ 95 %rh at 20"c20 ~ 98 %rh at 30 ~ 85"c80 %rh at 95"c | 15 ~ 85%rh at 10"c10 ~ 98 %rh at 30~ 85"c10 ~ 85 %rh at 90"c10 ~ 50 %rh at 120"c |
accuracy | ±2 %rh | ||
stability | ±2 %rh | ||
time | heating | 180l, 300l, 408l : 50min(-40"c ~120"c) 800l, 1000l : 60min(-40"c ~120"c) | |
cooling | 60 min (20"c ~ -40"c) : slow down up to -33"c | ||
refrigeration | system | mechanical single stage refrigerator system (air-cooled condenser) | |
refrigerant | r-404a(cfc-free :hermetic rotary compressor) | ||
capacity | 180l, 300l, 408l : 1.5kw 800l, 1000l : 3kw | ||
cooler | plate fin cooler | ||
heater | material | incoloy sheath heater | |
drying bulb | 180l, 300l, 408l :2kw | 180l, 300l, 408l :1.5kw | |
humidity bulb | 800l, 1000 :3kw | 180l, 300l, 408l :2kw | |
refrigerator | r-404a : 1hp(180l), 2hp(300l, 408l), 4hp(800l, 1000l) | ||
air flow | tangent blow : 180l, 300l, 408l3 set of siroco fan : 800l, 1000l | ||
material | exterior | sus #304 (hairline polish) | |
interior | sus #304 (2b polish) | ||
insulation | polyurethan (100mm) | ||
door | glass wool | ||
work environment | 3"c~35"c, 85%rh(non-corrosive and pure place) | ||
water tank | 180l, 300l, 408l : 15l(electrical conductivity 10?/cm or blow) 800l, 1000l : 15l x 2set (10?/cm or blow) | ||
interface | rs 485 (maximum 16sets control, option) | ||
safety devices | switch-off after alarm for overheating, water empty, current leak and over current and door open / vice lock door closing equipment | ||
size (dxh,mm) | 180l | internal : 500x630x600 | external : 1025x1035x1530 |
300l | internal : 600x630x800 | external : 1120x1070x1730 | |
408l | internal : 600x850x800 | external : 1120x1240x1730 | |
800l | internal : 1000x800x1000 | external : 1570x1445x2060 | |
1000l | internal : 1000x1000x1000 | external : 1570x1445x2060 | |
electric requirement | ac220v, 1phase, 60hz(option: 220vac,3phase, 60hz/380vac, 3phase,60hz) | ||
power consumption | 220vac, 1phase | 180l, 300l, 408l :23.0a, 800l, 1000l :39.0a | |
220vac, 3phase | 180l, 300l, 408l :13.3a, 800l, 1000l :22.5a | ||
380vac, 3phase | 180l, 300l, 408l :7.7a, 800l, 1000l :13.0a | ||
accessories | - digital display & recording 6-point type(dot type) - digital display & recording 2-pen type recorder - program controller - color monitor - water purifier for remove the inorganic from water- computer interface (program, rs-485 & rs-232 converter, cable) |