Relief Valve, RVP Series - 75,000 PSI | #20RVP9072
Parker Autoclave's RVP Series relief valves provide reliable venting of gases for set pressures from 3,000 psi (206 bar) to 75,000 psi (5171 bar). The valve’s metal seat design provides shut-off of liquids and gases to commercial standards.
Technical Specifications
技術(shù)參數(shù)
Maximum Operating Temperature (C): 204
Maximum Working Pressure (Bar): 1379
Maximum Operating Temperature (F): 400
Maximum Working Pressure (psi): 20000
Inlet Connection Size: SF562CX
Outlet Connection Size: 3/4" NPT
Orifice Size: 0.156" inch, 3.96 mm
Materials of Construction: 316 Stainless Steel
Minimum Operating Temperature: -252 °C, -423 °F
Maximum Operating Pressure: 20000 psi, 1379 bar
20RVP9072
Autoclave Engineers Medium to High Pressure Metal Seat Relief Valve - RVP
Parker Autoclave Engineers Metal Seat Relief Valve - RVP
Manufacturer Parker
Part Number 20RVP9072
20RVP9072
Metal-Seat Relief Valve
SKU: 20RVP9072 Categories: Parker Autoclave Engineers, AE Relief Valves Tags: Parker Autoclave Engineers, Relief Valves
Parker Autoclave's RVP Series relief valves are designed with a metal seat design for reliable venting of gases at set pressures from 3,000 psi (206 bar) to 75,000 psi (5171 bar). The operating temperature range is -423°F (-252°C) to 400°F (204°C).These precision relief valves are designed for thermal expansion or low volume relief applications at high pressures where flow is not critical. Thus, liquid curves for these models are not shown in the catalog
Parker Autoclave can supply various inlet and outlet connections on special order. A high temperature option is also available for temperatures to 750°F (399°C) for RVP models. To specify high temperature option: Add suffix “HT” for 750°F (399°C) high temperature option.
Caution:
1. AE relief valves are preset and factory sealed. Warranty is voided if seal is broken by customer.
2. Maximum system operating pressure should not exceed 90% of relief valve set pressure.
Markets:
Oil and Gas
Petrochemical
Chemical
Research
Features/Benefits:
Standard models of Relief Valves are constructed of 316 stainless steel with selected components made of anti-galling stainless steel material for optimum economy and ruggedness.
Designed with 3/8” and 5/16” Parker Autoclave high pressure inlet connections. The outlet connection on all models is a female 3/4” NPT. While adapters to other sizes and connection types are available, they must be sized for specific flow requirements.
Orifice diameters range from .062 (1.57mm) to .312” (7.92mm).
Designed to open as a function of increasing system pressure. Proper spring selection assures repeatability of opening, full lift and flow, and reseat pressures.
Materials engineering and stringent quality control procedures combine to assure the highest quality, reliability and service life. Each valve is preset and factory sealed to ensure proper valve operation.
Unique seat construction plus over-the-nozzle guiding and proper selection of materials permits standard set pressures to 75,000 psi. (5171 bar)
Designed to provide bubble tight shut off of gases.
Engineered to perform with fewer basic components, RVS valves facilitate minimum stocking of spare parts and ease of maintenance
Available with CE Mark. SOG option available upon request.
Applications:
Pressure Gas Systems
Cryogenic systems
Steam Handling Systems
Medium Pressure Fluid Handling Systems
Autoclave Engineers 20RVP9072-CE 接頭 Male to Female Adapters Male-to-Female Adapters join female connections with other size tubing or pipe. 自從1945年創(chuàng)建以來,Parker Autoclave Engineers制造能夠在各種溫度、壓力和環(huán)境變化條件下安全可靠地工作的高壓閥門系統(tǒng)。如今Parker Autoclave Engineers是為高壓應(yīng)用行業(yè)提供值得信賴的高壓閥門、接頭和管材。Parker Autoclave Engineers的閥門、接頭和管材一起在超過100000PSI(6895Bar)的壓力條件下可靠運(yùn)行的性能而聞名業(yè)界,同時也可為額定壓力15000PSI(1034BAR)的應(yīng)用提供低壓管路。利用單卡套壓力襯套確保使用方便且無泄漏,提供1/16至1/2英寸的連接尺寸。Since 1945 Parker Autoclave Engineers has designed and built premium quality valves, fittings and tubing. Parker Autoclave Engineers 10V and SW series needle valves are designed for operation to 15,000 psi (1,034 bar). Along with their many features these valves provide dependable and trouble free service in wide variety of applications. 性能參數(shù): ? Available in/or combinations of low, medium and high-pressure series. ? One piece design available ? Connection sizes are 1/8",1/4", 5/16", 3/8", 1/2", 9/16", 3/4", and 1". ? Fittings manufactured from cold worked 316 stainless steel. ? Operating temperatures from -423°F (-252°C ) to 1200°F (649°C). ? Available in special materials. BENEFITS Parker Autoclave Engineers valves are used in many applications such as the chemical/petrochemical, research, and oil and gas industries. The Autoclave low pressure line utilizes a single ferrule compression sleeve design for fast and easy installation. These valves are complemented by a complete line of fittings, tubing and accessories. Autoclave Engineers 20MFAJ16M9 接頭
Male to Female Adapters
Male-to-Female Adapters join female connections with other size tubing or pipe.
自從1945年創(chuàng)建以來,Parker Autoclave Engineers制造能夠在各種溫度、壓力和環(huán)境變化條件下安全可靠地工作的高壓閥門系統(tǒng)。如今Parker Autoclave Engineers是為高壓應(yīng)用行業(yè)提供值得信賴的高壓閥門、接頭和管材。Parker Autoclave Engineers的閥門、接頭和管材一起在超過100000PSI(6895Bar)的壓力條件下可靠運(yùn)行的性能而聞名業(yè)界,同時也可為額定壓力15000PSI(1034BAR)的應(yīng)用提供低壓管路。利用單卡套壓力襯套確保使用方便且無泄漏,提供1/16至1/2英寸的連接尺寸。Since 1945 Parker Autoclave Engineers has designed and built premium quality valves, fittings and tubing. Parker Autoclave Engineers 10V and SW series needle valves are designed for operation to 15,000 psi (1,034 bar). Along with their many features these valves provide dependable and trouble free service in wide variety of applications.
性能參數(shù):
Available in/or combinations of low, medium and high-pressure series.
One piece design available
Connection sizes are 1/8",1/4", 5/16", 3/8", 1/2", 9/16", 3/4", and 1".
Fittings manufactured from cold worked 316 stainless steel.
Operating temperatures from -423°F (-252°C ) to 1200°F (649°C).
Available in special materials.
BENEFITS Parker Autoclave Engineers valves are used in many applications such as the chemical/petrochemical, research, and oil and gas industries. The Autoclave low pressure line utilizes a single ferrule compression sleeve design for fast and easy installation. These valves are complemented by a complete line of fittings, tubing and accessories.