黄色视频不卡_午夜福利免费观看在线_亚洲国产精品999在线_欧美绝顶高潮抽搐喷水_久久精品成人免费网站_晚上一个人看的免费电影_国产又色又爽无遮挡免费看_成人国产av品久久久

    1. <dd id="lgp98"></dd>
      • <dd id="lgp98"></dd>
        1. 當前位置:首頁   >>   資料下載   >>   Rat CTx-I ELISA kit

          Rat CTx-I ELISA kit

          時間:2015-9-14閱讀:1439
          分享:
          • 提供商

            上??道噬锟萍加邢薰?/span>
          • 資料大小

            52.5KB
          • 資料圖片

          • 下載次數(shù)

            291次
          • 資料類型

            WORD 文檔
          • 瀏覽次數(shù)

            1439次
          點擊免費下載該資料

          Rat CTx-I

          FOR RESEARCH USE ONLY


          Assay range0.8nmol/L - 35nmol/L                96 determinations

          Purpose

          This kit allows for the determination of CTx-I concentrations in Rat serum, cell culture supernates and other biological fluids


          Principle of the assay

          The kit assay Rat CTx-I level in the sampleuse Purified Rat CTx-I antibody to coat microtiter plate wells, make solid-phase antibody, then add CTx-I to wells, Combined CTx-I antibody which With HRP labeledbecome antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of Rat CTx-I in the samples is then determined by comparing the O.D. of the samples to the standard curve.

          Materials provided with the kit

          1

          wash  solution

          20ml×1bottle

          7

          Stop Solution

          6ml×1 bottle

          2

          HRP-Conjugate reagent

          6ml×1 bottle

          8

          Standard(64 nmol/L

          0.5ml×1 bottle

          3

          Microelisa stripplate

          12well×8strips

          9

          Standard diluent

          1.5ml×1bottle

          4

          Sample diluent

          6ml×1 bottle

          10

          Instruction

          1

          5

          Chromogen Solution A

          6ml×1 bottle

          11

          Closure plate membrane

          2

          6

          Chromogen Solution B

          6ml×1 bottle

          12

          Sealed bags

          1

          Specimen requirements

          • extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it cant, specimen can be kept in -20  to preserve, Avoid repeated freeze-thaw cycles.
          • Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

          Assay procedure

          • Dilute and add sample:Dilute Original density Standard as follow table:

          32nmol/L

          5 Standard

          150μl Original density Standard+150μl Standard diluent

          16nmol/L

          4 Standard

          150μl Standard+150μl Standard diluent

          8nmol/L

          3 Standard

          150μl 4 Standard+150μl Standard diluent

          4nmol/L

          2 Standard

          150μl 3 Standard +150μl Standard diluent

          2nmol/L

          1 Standard

          150μl 2 Standard +150μl Standard diluent

          2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

          3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

          4.Configurate liquid: 30-fold(or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

          5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

          6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well. 

          7.incubateOperation with 3.

          8.washingOperation with 5.

          9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

          10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

          11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

          Steps description

          Standard, Sample diluent

           


          Add Standard, Sample diluent, incubate for 30 min at 37.

           


          Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

           


          Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

           


          Add Stopp Solution

           


          Read absorbance at 450nm within 15 min

           


          calculate

          Calculate

          Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

          Important notes

          • The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
          • washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
          • add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
          • if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.(×n×5).
          • Closure plate membrane only limits the disposable use, to avoid cross-contamination.
          • The substrate evade the light preservation.
          • Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
          • All samples, washing buffer and each kind of reject should according to infective material process.
          • Do not mix reagents with those from other lots.


          Storage and validity

          1.Storage:  2-8.

          2.validity: six months

          會員登錄

          ×

          請輸入賬號

          請輸入密碼

          =

          請輸驗證碼

          收藏該商鋪

          X
          該信息已收藏!
          標簽:
          保存成功

          (空格分隔,最多3個,單個標簽最多10個字符)

          常用:

          提示

          X
          您的留言已提交成功!我們將在第一時間回復您~
          撥打電話
          在線留言
          连云港市| 雅安市| 义乌市| 文水县| 瑞金市| 泗水县| 石城县| 石嘴山市| 集安市| 大足县| 会宁县| 丹棱县| 遵义县| 尉犁县| 体育| 蒙阴县| 平南县| 邻水| 准格尔旗| 金堂县| 巴中市| 镶黄旗| 乌恰县| 宝丰县| 闸北区| 丰原市| 乌鲁木齐市| 姜堰市| 玉田县| 托里县| 枝江市| 洛南县| 武汉市| 都匀市| 渭南市| 盘山县| 桐梓县| 沾化县| 清徐县| 龙口市| 赤峰市|